COMBUSTIBLE GAS DETECTOR 
8
6-2 Automatic Ambient Reset Feature 
This combustible gas detector features an Automatic 
Ambient Reset function that sets the unit to ignore 
ambient concentrations of combustible gas. 
  Automatic Ambient Setup - Upon initial power on, 
the unit automatically sets itself (approx. 1.5 minutes) 
to ignore the level of combustible gases present at 
the tip. Only a level, or concentration, greater than 
this will cause an alarm. 
CAUTION! 
This feature will cause the unit to ignore any 
combustible gases present at power on. In other 
words, with the unit OFF if you place the tip up to a 
known leak and switch the unit on, NO leak will be 
indicated! 
  Ambient Reset Feature - Resetting the unit during 
operation performs a similar function; it programs the 
circuit to ignore the level of combustible gases 
present at the tip. This allows the user to 'home-in' on 
the source of the leak (higher concentration). Similarly, 
the unit can be moved to fresh air and reset for 
maximum sensitivity. Resetting the unit with no 
combustible gas present (fresh air) causes any level 
above zero to be detected. 