Project Ideas
29
General Tools & Instruments
SAFETY
FEATURES:
• Sensitive, reliable and easy to operate
• Fast response time
• Redundant visual and audible alarms
• Auto-calibrating
• Malfunction and low battery alerts
SPECIFICATIONS:
♦
Range: 0 to 100%LEL
♦
Response Time: < 5 seconds
♦
Sampling: Natural diffusion
♦
Operating Temperature:
-4° to 131°F (-20° to 55°C)
♦
Operating Humidity: <95%RH
♦
Operating Voltage: DC3V
♦
Operating Current: <150mA
♦
Low Alarm: (20±5) % LEL
♦
High Alarm: (50±10) % LEL
♦
Dimensions: 7.6 (L) x 1.2 (Dia) in. (193 x 30mm)
♦
Weight: 4 oz. (113g)
♦
Power Source: 2 “AA” batteries (included)
INCLUDES:
• Wrist Strap • Batteries • User’s Manual
• 1-Year Limited Warranty
UPC NO.
41501 6 PNG2000A
COMBUSTIBLE GAS DETECTOR PEN – PNG2000A
Ideal for detecting leaks of natural gas, propane or butane from plumbing and
appliances.
PNG2000A
DIGITAL CO DETECTOR WITH AUTO ZERO – DCO1001
Ideal for HVAC home, office, tunnels, mines, etc.
DCO1001
FEATURES:
• Proprietary sensor with lifetime of more than
300 hours of operation (ten years of normal use)
• Detects all commercially available HFC, HFO,
HC, HCFC and CFC refrigerants as well as
blends and newly approved replacements such
as R-22 and R-1234yf
• Triple-redundant leak indication (loud fast beep,
bright flashing LED, digital leak size reading)
• True mechanical pump draws in samples,
increasing sensitivity
• Three sensitivity levels
• Fast warmup
• Comfortable neoprene grip
• Automatic calibration and reset to ambient
levels
• Mutable beeper
• Garage-durable construction
• Made in U.S.A.
• SAE J2791 and J2913 certified
• Complies with European standard EN 14624
• CE, RoHS, WEEE approved
SPECIFICATIONS:
♦
Sensitivities: 0.05 oz./yr (1.4 g/yr) for R-134a;
0.025 oz./yr (0.7g/yr) for R-22
♦
Refrigerants Detected: R-134a, R-410a, R-404a,
R-407c, R-507, CFC-12 (R-12 or Freon), R-22,
R-1234yf
♦
Detection Modalities: Sound, light, leak size
measure
♦
Sensor Type: Proprietary solid electrolyte
semiconductor
♦
Sensor Life: >300 hours (ten years’ normal use)
♦
Warmup Time: 17–20 seconds
♦
Response Time: Instantaneous
♦
Display Type, Size: 7-segment red LED, 0.6 in.
(15mm) high
♦
Dimensions of Instrument: 6.8 x 2.6 x 2.2 in.
(173 x 66 x 56mm) w/17 in. (432mm) probe
♦
Weight of Instrument: 1.5 lb. (680g)
♦
Power Source: 4 “AA” batteries (included)
♦
Battery Life: 5 hours continuous operation
(typical)
DIGITAL REFRIGERANT LEAK DETECTOR WITH PUMP – RLD400
Ideal for electronic sensing—the most widely used, sensitive and accurate method
of refrigerant leak detection. New proprietary semiconductor sensor detects many new
ozone layer-friendly refrigerants approved under the U.S. EPA's Significant New
Alternatives Policy (SNAP).
RLD400
INCLUDES:
• Padded Hard Case • Leak Test Vial
• Batteries • User’s Manual
• 2-Year Limited Warranty (including sensor)
UPC NO.
01587 2 RLD400
Indicates optional NIST calibration is available
FEATURES:
• Adjustable CO warning level
• 2-line backlit LCD
• Auto max level display with reset
• Auto-calibrates at 0, 100 and 500 ppm
• 15-second self-test at startup
• Also measures and displays temperature
• °F/°C switch
• 15-minute Auto Power Off
SPECIFICATIONS:
♦
Measurement Range: 0 to 999ppm
♦
Resolution: 1ppm
♦
Accuracy: ±20% from 0 to 100ppm;
±15% from 100 to 500 ppm
♦
Dimensions:
7 x 1.7 x 1.1 in. (178 x 43 x 28mm)
♦
Weight: 4 oz. (113g)
♦
Power Source: 3 “AAA” batteries (included)
♦
Battery Life: 250 hours with the backlight off;
and 35 hours with the backlight on
INCLUDES:
• Wrist Strap
• Carrying Pouch
• Batteries
• User’s Manual
• 1-Year Limited Warranty
UPC NO.
41655 6 DCO1001
Gas, CO & Refrigerant Leak Detectors