SDS

_____________________________________________________________________________________________
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Nickel
7440-02-0
TWA: 1.5 mg/m
3
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 10 mg/m
3
TWA: 0.015 mg/m
3
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 1
mg/m
3
Cu dust and mist
TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu
dust, fume, mist
IDLH: 100 mg/m
3
dust, fume and
mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
Aluminum foil
7429-90-5
TWA: 1 mg/m
3
respirable fraction TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction (vacated)
TWA: 5 mg/m
3
Al Aluminum
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits NIOSH IDLH Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992)
Appropriate engineering controls
Engineering Measures
Showers
Eyewash stations
Ventilation systems
Individual protection measures, such as personal protective equipment
Eye/face protection
Wear safety glasses with side shields (or goggles).
Skin and body protection
Wear protective gloves and protective clothing. Long sleeved clothing. Impervious gloves.
Respiratory protection
If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved
respiratory protection should be worn. Positive-pressure supplied air respirators may be
required for high airborne contaminant concentrations. Respiratory protection must be
provided in accordance with current local regulations.
_____________________________________________________________________________________________
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place. Store locked up.
Keep out of the reach of children.
Incompatible Products
Strong acids. Strong oxidizing agents. Strong bases.
Revision Date 17-Mar-2016
1318781 - LG Chem 18650F1L (3.35Ah)
7. HANDLING AND STORAGE
Precautions for safe handling
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. Use personal protection equipment.
Page 5 / 12
Conditions for safe storage, including any incompatibilities