Owner manual

1
DH95 - Crawl Space, Attic or Basement
Whole House Dehumidifier
Installation & Owners Manual
Read the installation operation and maintenance instructions carefully before installing and using this unit.
Proper adherence to these instructions is essential to obtain maximum benefit from the DH95 system.
Installation contrary to these guidelines or lack required maintenance will void warranty.
Specifications
• Model:DH95
• Capacity:95pints/day,(4.14lbs./hr)@80°/60%RH
• Electrical:110-120VAC,9.6FLAAmps,60Hz,grounded
• OperatingReturnAirTemp.Range:50°Fmin.,90°Fmax.
• AirFlow:
• 375CFMwithoutexternalducting
• 295CFM@.30IWGexternalstatic
• 234CFM@.50IWGexternalstatic
• RefrigerantCharge:17.5oz.R-410A
• Ductconnections:Returnductange:10”Round,Outlet10”Round,
• FilterSize:HighEfciency(MERV11):Pleated13-3/8”X13-3/8”X2”
• Size(Clearance):14.5”Heightx30”Widthx15.5”Depth,14”minimumfrontorrearclearanceforlterservice.
• Weight:73pounds(ShippingWeight94pounds),(16”H,32.5”W,20”D)
Read and Save These Instructions
FORMNO.DH95REVA
Unit Location
TheDH95canbeinstalledinavarietyoflocationstomeettheowner’sneedsaslistedbelow.Inallcaseskeepthe
followingcautionsinmind:
• Theunitisdesignedtobeinstalledindoorsinaspacethatisprotectedfromrain,oodingand/orotherforms
ofexcesswater.Unitisnotdesignedtobeexposedtochlorinatedpoolconditionsorspaceswhereunitwillbe
exposedtocorrosivechemicalsorconditions.
• Installtheunitwithspacetoaccessthefrontpanelformaintenanceandservice.Alsoalloweasyaccessto
theltercoverpanel.DO NOT INSTALL THE UNIT WITH THE FRONT PANEL OR FILTER COVER PANEL
INACCESSIBLE.
• Avoiddischargingtheairdirectlyatpeople,overthewaterinpoolareas,orotherareasorobjectswhere
dehydrationorevaporationofmoistureisnotdesired.
• Ifusednearwetareas,becertainthereisNOchancetheunitcouldfallintothewaterorbesplashedandthatitis
wiredintoaGROUNDFAULTINTERRUPTERprotectedcircuit.
• AsecondarydrainpanMUSTbeplacedundertheunitifinstalledabovealivingareaoraboveanareawhere
waterleakagecouldcausedamage(seelocalcodesforotherrequirements).
• DO NOTpositiontheDH95directlyonstructuralmemberswherenoiseorvibrationmaybeobjectionable.The
DH95isequippedwithadjustablesupportfeettoraiseandleveltheunitfromthemountingsurface,these
adjustablefeetshouldbeutilizedtoprovideimproveddrainagefromthedrainpanandshouldbeadjustedtotilt
slightlytowardthedrainutilized.
• TheDH95shouldbelocatedneartheexistingairhandlingsystemtominimizetherequiredductworkfor
connectingoftheDH95totheexistingairhandlingsystem.Whentheremotecontroloptionisused,thecontrol
(humidistat)unitmustbelocatedinthespacethatistobeconditioned.Thecontrol(humidistat)maybelow
voltage(24volt)andshouldbeconnectedtotheDH95withcodeapproved,lowvoltagethermostatcable.
• WhenlocatingtheDH95inareasofextremeheatorhighhumidity,>120-degrees/90%humidity,additional
externalinsulationmayberequiredtopreventundesiredcondensationontheexterioroftheunit.
By GeneralAire
®