Specification

Connecting A Portable
Connecting A Portable Connecting A Portable
Connecting A Portable
Generator is Now
Generator is Now Generator is Now
Generator is Now
Safe and Easy with
Safe and Easy withSafe and Easy with
Safe and Easy with
GenerLink
GenerLink GenerLink
GenerLink
a new meter collar device that makes
connecting a portable generator safe and easy
SAFE
GenerLink™ eliminates the use of extension cords and other
connections that can be hazardous to customers and utility
personnel.
GenerLink™ detects when a generator is operating and
automatically disconnects from the utility grid, eliminating
dangerous backfeed.
EASY
GenerLink™ is equipped with GenerLok™, a unique interlocking
power cord system that provides a quick and easy connection of a
portable generator.
GenerLink™ is installed in 20 minutes or less by utility personnel
and does not require the customer’s presence.
GenerLink™ is easily installed behind a customer’s electric meter
and requires no rewiring of the customer’s electrical system.
With GenerLink™, customers have the flexibility to run virtually
any appliance, up to the capacity of their generator by simply
energizing appliances from their breaker panel.
www.generlink.com
Global Power Products, Inc.
225 Arnold Road
Lawrenceville, GA 30044
www.globalpowerproducts.com
1.800.886.3837
GENERLINK™ with GENERLOK™ SPECIFICATIONS AND
TECHNICAL INFORMATION MODEL
MA23/24 - N/S
Physical:
Diameter: 6 ½ in.
Depth: 5 ¼ in.
Weight w/o surge: 5 ½ lbs
Weight with surge: 5 ¾ lbs
Socket Style: Ring or Ring-less, 200 Amp, 4 jaw
Electrical:
Source Compatibility 200 Ampere or less
Withstand Current: 10,000 Amperes rms symmetrical at .7 - .8 pf, 240 Volts, 60 Hz
6000 Amperes for 6 cycles at .7 - .8 pf, 240Volts, 60 Hz
Generator Input:
10kW Continuous
, 120/240 Volt
Connection: Proprietary GenerLoc™ QuickConnect Cord
Operational:
Transfer Type: Break–Before–Make
Transfer Delay: 2-3 Seconds
Life Cycle: 300,000 Operations
Temperature Range: -30°C to 60°C External Ambient
Features:
Generator Input Generator Input Voltage > 200 Volts
Protection: Supplemental Overcurrent <
40 A
Utility Input Utility Input Voltage >
180 Volts
Protection: Over-Temperature Trip >
105°C
Load Integrated Whole-House
Protection: Surge Protection Model
MA23/24 - S Only
Status Indication: Long-life LED indicators show utility power availability and/or fault presence
3 hours at 25° C ambient
Sold Separately
* when protected by max 200 A circuit breaker in
series with max 100 A branch circuit breaker

Summary of content (1 pages)