Cut Sheet
Published: 2019-08-24
General Purpose Security & Control Cable
Part Number: 1118
18 AWG 2 Stranded Conductors
Ratings CM, CL2, Sunlight Resistant
Approvals ETL Listed
Construction
Conductor 18 AWG 19 Strand Bare Copper
Conductor Count 2
Insulation Polypropylene (0.006" nom.)
Insulation Colors Black, Red
Lay Length 4" nom.
Shielding N/A
Rip Cord Yes (except Speed Bag put ups)
Jacket PVC (0.015 " nom.)
Overall Diameter 0.148" nom.
Print Legend GENESIS P/N 1118 2C18 3038058 (ETL) CL2 OR CM C(ETL)US SUN RES (RoHS) W/O
#XXXXXX-XXXXXX XXXX FT DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9
Properties
Operating Voltage 300 Volts max.
DC Resistance 6.66 Ohms/1000' at 20°C
Capacitance 22.7 pF/ft. nom.
Impedance 67 Ohms nom.
Temperature -20°C to 60°C
Flame Rating UL 1685 Vertical Tray
RoHS Compliant Yes
Country of Origin USA