Use and Care Manual

Required Programming
3
Required Programming
3
MODEL AC SR3 THE GENIE COMPANY
FCC ID: B8Q AC SR3 Residential Door Operator
IC: 2133A-CSD1D 120V. 60HZ. 5A
S/N:10XXXX XXXXXXX
STB BWC IWC
NOT
USED
NOT
USED
NOT
USED
NOT
USED
FROM STBs
FROM WALL
CONSOLE
STB
BWC
IWC
FROM STBs
FROM WALL
OM STB
ROM WA
OM W
CONSOLE
B/W
W
Open/Close Button
Opens and closes door from inside garage.
Sure-Lock™ Button
– LOCK disables controls
after door is completely
closed.
– UNLOCK allows controls to
work normally.
Indicator Light
–Red indicator light is
always ON.
–When Sure-Lock™ is ON,
the indicator light flashes.
Independent Light Control Button
Controls door opener lights from inside garage.
To powerheadTo powerhead
B/W
W
Open/Close Button
Opens and closes door from inside garage.
Sure-Lock™ Button
– LOCK disables controls after
door is completely closed.
– UNLOCK allows controls to
work normally.
Indicator Light
–Red indicator backlight is ON.
–When Sure-Lock™ is
ON, the indicator light is OFF
Independent Light Control Button
Controls door opener lights from inside garage.
To powerheadTo powerhead
WALL CONSOLE / Overview
This opener has a serial
number sticker in which
the serial numbers begin
with 10 or higher.
Wall consoles from other manufacturers may not work with openers
of these serial number groups. Use only the wall console provided with
this unit. Each wall console has three buttons.
In your carton you will find one of the following
wall consoles:
Series II Wall Consoles with White Buttons
Indicator Light
Large white button will display Red when wall console is properly
wired and Sure-Lock
is OFF. When Sure-Lock
is ON, this light is off
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON, the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE mode will override
STB fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.
NOTE: If opener has a Motion Detector sensor, it will keep powerhead
lights ON as long as motion is detected.
Sure-Lock
Button
When Sure-Lock
is ON, the powerhead cannot be activated by the
wall console or a remote.
•Pressandrelease(oruntilredlightgoesoff)toactivateSure-Lock
.
•PressandreleasetoturnSure-Lock
OFF.
Series III Wall Consoles with Black Buttons
Indicator Light
Indicator light will display Red when wall console is properly wired and
Sure-Lock
is OFF. When Sure-Lock
is ON, indicator light flashes.
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is
ON, the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE mode will override STB
fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn powerhead lights ON. Powerhead lighting will
remain ON until this button is pressed again or a door action has been
completed.
NOTE: If opener has a Motion Detector sensor, it will keep powerhead
lights ON as long as motion is detected.
Sure-Lock
Button
When Sure-Lock
is ON, the powerhead cannot be activated by the
wall console or a remote.
•Pressandholdfor5seconds(oruntilIndicatorLightashes)to
activate Sure-Lock
.
•PressandreleasetoturnSure-Lock
OFF.
TIP
8
G999-393 Manual-ScrewBeltChain-EN.indd 8 7/13/12 10:17 AM