Replacement Part List

Force Settings:
Force settings are pre-programmed at the factory to force level 6 (See Chart Below) and applied
during the Open/Closed Limit settings steps. For
normal use, these settings should not need adjustment.
Conditions possibly requiring adjustments are:
1. Doors with very sti weather seals.
2. Doors that start down, STOP, and reverse before closing.
3. Doors that start up, but STOP before they completely open.
AVERTISSEMENT
!
Pour éviter les blessures ou des dommages
• NE JAMAIS régler la force pour compenser des
dommages, y compris une porte mal équilibrée, un rail
de porte coinçant ou des ressorts cassés.
• Tous les mois, EFFECTUEZ LE TEST D’INVERSION AU
CONTACT.
WARNING
!
TO AVOID INJURY OR DAMAGE
• NEVER adjust the force settings to adjust for damage,
including an unbalanced door, binding door track or
broken spring.
• Perform a CONTACT REVERSE TEST monthly.
1. Press and hold both UP & DOWN arrow buttons until the ROUND LED turns RED. Release
buttons.
• LEDs will show current force level. SEE CHART.
2. Press either the UP or DOWN arrow button until the desired UP force setting is shown. SEE
CHART.
3. Press & release the PRGM button to lock the desired UP FORCE setting.
• Both LEDs will turn BLUE then go out conrming that the UP force setting has been
changed and is locked.
• LEDs will now show the current DOWN FORCE setting. SEE CHART.
4. Press either the UP or DOWN arrow button until desired DOWN force setting is shown. SEE
CHART.
5. Press & release the PRGM button to lock the desired DOWN FORCE setting.
• Both LEDs will turn BLUE then go out conrming that the DOWN force setting has been
changed and is locked.
6. Perform all steps on page 20 to test operator.
RED
PRESS & RELEASE
See Chart for
Force level
indicators.
Press PRGM to
lock settings
FORCE SETTING CHART
Force Level Long LED Round LED
1 (LOWEST) OFF BLUE
2 BLUE OFF
3 BLUE BLUE
4 OFF PURPLE
5 PURPLE OFF
6 PURPLE PURPLE
7 OFF RED
8 RED OFF
9 (HIGHEST) RED RED
CAUTION
!
DO NOT adjust force level above what is necessary to
allow for normal door operation.
CAUTION
!
NE réglez PAS la force à un niveau supérieur à ce qui est
nécessaire pour permettre un fonctionnement normal de
porte.
CHANGING FORCE SETTINGS
IMPORTANT NOTICE
IF FORCE SETTING IS ALTERED, ALL STEPS ON PAGE 20 MUST BE PERFORMED TO LOCK IN THE FORCE PROFILE
FOR PROPER DOOR OPERATION.
!
!