Replacement Part List
27
Regular inspection/maintenance for the door and opener should be performed at regular
intervals to ensure the system runs at peak safety, performance and eciency.
MAINTENANCE ITEM INTERVALS DETAILS
Contact Reverse Test Monthly See Page 20 to run system test.
Lubricate Door Hardware Monthly Lubricate Rollers & Hinges with a light weight general
purpose grease.
Safe-T-Beam® system check Monthly Check wiring for loose connections, cracks or worn
insulation.
Clean lenses of dirt & debris.
Door Balance Monthly See Maintenance Detail A
Battery Backup System Monthly Unplug opener from outlet. Test opener with remote
or wall console. Replace battery if needed.
Remote Battery replacement As Needed See Maintenance Detail B
Perform the Door inspection as follows:
With the door closed, pull manual emergency release handle DOWN to disengage opener from
door.
• Raise and lower the door manually. Door should move freely and smoothly.
• Raise door manually about 3’ to 4’ feet from oor and let go.
. Door should remain
stationary or slowly drift closed. FIG. 1.
If door opens or closes rapidly, CONTACT A TRAINED DOOR SYSTEM TECHNICIAN to have
your door springs serviced.
• Close the door.
• Pull emergency release cord down and release quickly to engage opener to door.
• Operate door using remote or wall control.
A
WARNING
!
Garage door hardware (springs, cables, brackets, pulleys, etc.) are under
extreme pressure and tension.
DO NOT attempt to repair or adjust door springs or any hardware, and DO NOT
OPERATE garage door automatically or manually if door is improperly
balanced or springs are broken.
CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.
AVERTISSEMENT
!
La quincaillerie de la porte de garage (ressorts, câbles, supports, poulies, etc.)
sont sous des pressions et des tensions extrêmes.
NE PAS réparer ni régler les ressorts de la porte ou toute autre pièce de
quincaillerie et NE PAS ACTIONNER la porte manuellement ou
automatiquement si elle n’est pas correctement équilibrée ou si des ressorts
sont cassés.
CONTACTEZ UN TECHNICIEN SPÉCIALISÉ EN SYSTÈME DE PORTES
Door Inspection
FIG.1
B
Remote Battery Replacement
(3-button)
Replace remote battery with a CR2232 coin cell battery.
1. Open remote case using a washer or coin that ts into the slot on the top of the remote.
2. Replace battery.
Be sure positive side (+) is UP.
3. Align components and snap case closed.
Replacing Batteries
Wall Console Battery Replacement
Replace wall console batteries with 2-AAA batteries.
1. Open remote case.
2. Replace batteries.
Ensure insertion in correct position.
3. Align components and snap case closed.
AAA