Instructions / Assembly
Lift and support powerhead while a second person fully opens the door.
Insert a 2 x 4 board, cardboard or towel between door and rail to protect
door.
Position opener over the DOOR CENTERLINE and allow it to rest on
protective material.
There are several methods to mount the powerhead to the ceiling. The most popular methods are shown here. Use the method , or combination of methods, that best suit the mounting requirements for your garage.
Attach to garage framework only. DO NOT attach to drywall or particle board.
This opener includes 2 - 28in long perforated angle straps, 2- lag screws, and 2- nuts and bolts. Additional hardware may be required depending on the installation requirements.
Sectional Door (Metal Door):
1. Center bracket on door and align near
the same height as top rollers.
2. Using bracket as a guide, mark holes on
door.
3. Drill 1/8" pilot holes partially through
the door.
4. Secure with 1/4" - 20 x 3/4" self-tapping
screws.
Some garage door manufacturers provide
door brackets that CAN be used with your
Genie Door Arms.
ATTACH DOOR BRACKET
AT SAME HEIGHT
AS TOP ROLLER
DOOR CENTERLINE
Top Roller
1. Position Safe-T-Beam
®
(STB) Transmitter and Receiver on each side of garage door 5"- 6"
above oor. Face the lenses towards each other.
2. Mark bracket mounting holes; drill 3/32" pilot holes and secure with (4) 1/4" x 1-1/4" lag
screws (provided) into wood. If mounting into concrete or block, other fasteners are required
and are available at leading retail stores.
3. Use garage pre-wiring if available. Otherwise, route 2 lengths of supplied wire from
powerhead, along the ceiling, across the header and down both sides of the door, to each
sensor. Secure the wire to the ceiling and walls using the insulated staples (green bag).
4. On the powerhead: insert both wires down through the control wire channel. Remove 1/4"
insulation from both sets of white and striped wire. Twist two striped wires together. Using
a small at head screwdriver, press in the orange tab at terminal 1 and insert the wires.
Twist the two white wires together and insert into terminal 2. Ensure the wires are in their
terminal, adjust as necessary.
5. At each sensor, remove 1/4" insulation from the white and striped wires and secure in each
terminal. Ensure the wires are secure at each terminal; adjust as necessary.
6” max
5” min
above oor
6” max
5” min
above oor
Floor mount option
PHOTOCELL (STB)
PHOTOCELL (STB)
Wall mount
Wall mount
Transmitter/Receiver
To powerhead
1. Install light bulbs into powerhead light socket(s). Skip this step for
integrated LED models.
2. Insert lower lens tabs into slots in motor cover on powerhead.
3. Snap upper lens tabs into place. It may be necessary to squeeze tabs down
slightly to align tabs with slots at top of opener frame.
Compact CFL, SPECIALTY LED*, or Incandescent Bulbs can be used. 60W Max.
NOTE: Aladdin Connect® models require a minimum 40 Watt equivalent bulb, 60 Watt maximum.
FOR GROUNDED OUTLET CONNECTION:
Plug in the power cord to standard 115 VAC outlet. Coil excess cord and tape or
twist tie it to top of powerhead.
(DO NOT PLACE DIRECTLY ABOVE LIGHT BULBS.).
FOR PERMANENT WIRING BY AN ELECTRICIAN ONLY:
1. Cut existing power cord outside chassis.
2. Remove strain relief and strip insulation from power cord wires inside chassis.
3. Install suitable power cable and connectors (Adhere to local code and regulations)
4. The wire connections must be made INSIDE CHASSIS and there must be at least 6" of new power supply
line wire INSIDE CHASSIS.
5. Check local code for the use of conduit or other protective material.
• (Conduit, strain relief, and wire nuts are not provided.)
Refer to the Programming, Operation and Maintenance Manual for programming and Battery Backup installation instructions.
INSTALLATION IS COMPLETE. OPENER IS NOW READY TO PROGRAM
M
WARNING
Green Parts Bag
TOOLS: Tape Measure, Level, Ruler/Square, Ladder, Pencil, 5/32” Drill, 7/16” & 1/2” Socket/Ratchet, Hacksaw.
MOUNTING OPENER TO CEILING
NOTE: Rail should be level to oor.
Ceiling Joist
A. Move carriage towards powerhead.
B. Raise opener near level with the oor.
C. Fully open door.
D. Insert protective material between opener rail and door.
E. Rest opener on protective material and center rail on door.
A
B
C
D
RAISE AND CENTER OPENER TO DOOR
Completed Mounting
Exposed Ceiling Joist
Pre-Drill Holes
Trim Angle
Trim Angle
5/16-18 Nuts & Bolts
All hardware shown included
PARALLEL JOIST PERPENDICULAR JOIST
Method A-For open ceilings with exposed joist, drill 5/32”
pilot holes and secure included mounting straps to joist
using 5/16” x 1-3/4” lag screws. Raise powerhead unit so
that there is sufficient clearance between door and rail.
Cut and/or bend mounting straps as needed to align with
the powerhead and to level the rail. Secure powerhead to
mounting straps using 5/16”-18 x 3/4” bolts and nuts. Ensure
powerhead is centered with the door and remove the 2 x 4
board and/or other protective material and close the garage
door.
Method B-For finished or unfinished ceilings, attach perforated angle (not
supplied) to joists using 5/16” x 1-3/4” lag screws and secure mounting
straps to the perforated angle with 5/16"-18 bolts and nuts (not supplied).
Raise powerhead so that there is sufficient clearance between door
and rail. Cut and/or bend mounting straps as needed to align with the
powerhead and to level the rail. Secure powerhead to mounting straps
using 5/16”-18 x 3/4” bolts and nuts. Ensure powerhead is centered with
the door and remove the 2 x 4 board and/or other protective material and
close the garage door.
Blue Parts Bag
TOOLS: Tape Measure, Level, Ruler/Square, Ladder, Pencil, 1/8” or 9/32” Drill, 7/16” & 9/16” Socket/Ratchet.
ATTACHING OPENER TO DOOR
*
Door Centerline
Door Centerline
* In some cases, a garage door opener
reinforcement bracket should be used.
Check the recommendations from the
door manufacturer. Attach door bracket to
reenforcement bracket.
REINFORCEMENT
BRACKET
Sectional Door (Wooden Door):
1. Center bracket on door. Attach
near the same height as top
rollers.
2. Using bracket, mark holes on
door.
3. Drill 9/32” holes completely
through the door.
4. Fasten bracket with 1/4” X *”
carriage bolts and nuts (not
provided).
*Measure thickness of door and
add 1/2 inch to purchase correct
length of carriage bolts. Stainless
Steel bolts are recommended to
prevent staining of the door.
DOOR
CENTERLINE
Solid Wood Door
5. Slide the carriage to about 16 inches from the door.
6. Position carriage and door arms to form an angle of approximately 20 to
30 degrees.
7. Attach the curved and straight door arms together using 3/8"-16 x 7/8"
bolts and nuts. Space the fasteners as far apart as possible.
NOTE: Overall length of both arms should be minimized, but not so short that
the straight arm is vertical or too long that it exceeds 30° from the header.
1. Attach the curved door arm to the door
bracket with 3/8” X 1” clevis pin and hair
pin.
2. Attach the straight door arm with 3/8” X
1” clevis pin and hair pin.
3. Attach the emergency release cord to
the carriage release arm. Tie a simple
overhand knot to secure.
4. Position emergency release handle to be approximately 6 feet from oor*.
Attach with a simple overhand knot. Cut o excess.
* If the emergency release handle interferes with vehicle roof rack, sunroof or
other object that may interfere with the proper and safe operation of the release
mechanism, move release handle further upwards.
NOTE: Emergency release handle MUST be placed where home occupant(s) can
reach.
Yellow Parts Bag
Green Parts Bag
TOOLS: Ladder, Pencil, Small Common Screwdriver, Wire Strippers/Wire Cutters, Hammer,
3/32” Drill, 1/4” Socket/Ratchet
WIRING THE OPENER (Safe-T-Beam® & Wall Console)
Wire from
Photocells
Strip
1/4” of
insulation
Wire Feed
Channel
Wire from
Wall Console
INSTALL LIGHT BULBS
AND LENS COVERS
Single Bulb Models Dual Bulb Models
POWER THE OPENER
ONCE POWER IS APPLIED:
• Verify that the RED and GREEN lights are lit on the Safe-T-Beam®. If they are not lit, return to step 5 and check wiring.
• Verify that the wall console is lit RED. If powerhead LED is blinking blue, press the Sure-Lock® button on the console. If the
console is not lit RED, return to step 5 and check wiring.
NOTE: Integrated LED lighted models require specialty kits for replacement. See owners manual parts section.
3
4
5
6 7
Internal Opener Connections
PHOTOCELL WIRES:
Striped Wires to Terminal 1
White Wires to Terminal 2
WALL CONSOLE WIRES:
White Wire to Terminal 3
Striped Wire to Terminal 4
Push in on Tabs to Insert Wire
Safe-T-Beams®
Staples
Warning
Label
TYPICAL INSTALLATION
ALTERNATE MOUNTING TYPES
ADDITIONAL HARDWARE MAY BE REQUIRED
Finished Ceiling
NOTE: Skip steps 1 -4 if your model included the Wireless Wall Console. See owners manual for more instruction.
1. Use garage pre-wiring if available. Otherwise, route supplied wire from powerhead to the
desired location for the wall control. Secure wire with insulated staples (green bag).
2. On the powerhead: insert wire down through the control wire channel. Remove 1/4" insulation
from white and striped wire. Using a small at head screwdriver, press in the orange tab and
insert the white wire in terminal 3 and the striped wire in terminal 4. Ensure the wires are
secure in each terminal; adjust as necessary.
3. At the wall console end of the wire, remove 1/4" insulation from the white and striped wires
and secure the white wire to the "W" terminal and the striped wire to the "B/W" terminal as
shown. Ensure the wires are secure at each terminal; adjust as necessary.
4. Mark the wall console mounting holes, drill 3/32" pilot holes and mount with #6 x 1-1/4"
screws. If mounting to drywall, anchors will be required (not provided).
5. Post the "ENTRAPMENT WARNING LABEL" (Included in the Operation and Maintenance Manual)
next to the wall console. (Use alternate label for iDCM model openers, see owners manual)
B/W W
Wall Console Wires:
Striped Wire to B/W Terminal
White Wire to W Terminal
Wired Wall Console
* Genie LED light bulbs are designed to reduce or
eliminate reduced remote range issues caused by
common LED bulbs. They also oer better product life
by making them resistant to vibration caused by the
opener, and cold or damp weather. See website for
details at www.GenieCompany.com
Doors made of Masonite, lightweight wood, berglass, and sheet metal must be properly braced before
mounting door bracket. Contact door manufacturer or distributor for any questions or concerns. The Genie
®
Company is not responsible for any damage caused due to an improperly braced door.
CAUTION
Les portes en masonite, bois léger, bre de verre et en tôle doivent être correctement renforcées avant
l’installation du support de la porte. Contactez le fabricant ou le distributeur de la porte si vous avez
des questions ou des préoccupations. The Genie® Company n’est pas responsable des dommages qui
pourraient résulter de l’installation d’une porte mal renforcée
CAUTION
!
CAUTION
When using insulated staples, make only snug enough to hold electrical wire in place. Staples too tight can
cause damage to wire and cause Safe-T-Beam
®
System to malfunction.
!
WARNING
Use of any other wall control can cause unexpected operation of the door and loss of lighting feature.
Locate wall console within sight of door and far enough from door to prevent contacting it while operating
the console. Control must be at least 5 feet above oor to prevent small children from operating it.
!
AVERTISSEMENT
L’utilisation d’une autre commande murale pourrait produire des résultats inattendus de la porte ainsi que le
dysfonctionnement de l’éclairage. Localisez la console murale en vue de la porte et susamment loin de la porte pour éviter
tout contact pendant l’utilisation de la console. La commande doit être à une hauteur minimale de 1,5 m au-dessus du sol an
que les jeunes enfants ne puissent pas l’atteindre.
!
Lors de l’utilisation des agrafes isolées, serrez susamment pour tenir le l en place mais sans plus. Si
vous serrez trop, vous risquez d’endommager les ls et de provoquer le dysfonctionnement du système
Safe-T-Beam®.
CAUTION
!
Warning Label
inside owners manual
CAUTION
DO NOT exceed maximum wattage, as the unit may overheat and permanent damage may occur. Each light bulb
should be no more than 100W MAX.
Do not use halogen, short neck, or specialty light bulbs as they may overheat the opener.
!
NE PAS dépasser la puissance maximale, dans la mesure où l’unité peut surchauer et des dommages
irréversibles peuvent se produire. Les ampoules ne doivent pas être supérieures à 100 W max.
Ne pas utiliser d’ampoules halogènes, au cou court ou de spécialité parce qu’elles risquent de surchauer
l’ouvre-porte.
CAUTION
!
CAUTION
DO NOT run opener until travel limits have been set to avoid damage to unit.
!
WARNING
Opener is equipped with grounded electrical plug for your protection, and only ts grounded electrical
outlets. DO NOT alter plug in any way! If you have no grounded outlets, have one installed by a
licensed electrician. Opener must be properly grounded to prevent personal injury and equipment damage.
NEVER USE AN EXTENSION CORD! Check local building codes for any requirement that you must have a
permanent hard-wired connection.
!
AVERTISSEMENT
L’opérateur, qui est équipé d’une prise électrique mise à la terre pour votre protection est compatible
uniquement avec des prises électriques mises à la terre. NE PAS modier la che dune quelconque
manière. Si vous n’avez pas de prises mises à la terre, faites-en installer par un électricien agréé.
L’opérateur doit être correctement mis à la terre pour éviter les blessures corporelles et des dommages
matériels. NE JAMAIS UTILISER DE RALLONGE! Vériez les codes locaux des bâtiments pour connexions
câblées permanente. Les connexions câblées permanentes doivent être eectuées par un électricien
agréé qui se servira d’outils appropriés et respectera les consignes.
!
NE PAS faire fonctionner l’ouvre-porte au-delà des limites de parcours pour ne pas endommager l’unité.
CAUTION
!
NOTICE: All low voltage wiring must be CL2 or equivalent rated
38968503812_ELOPoster.indd 2 5/7/2018 11:19:38 AM