MAINTENANCE
Check the Oil Lubricator Canister
Drip Rate - Air Models
Maintaining the proper oil drip rate into the
lubricator canister is essential to safe operation
and good machine performance. Failure to
maintain the proper drip rate could result in
machine component damage.
1 While raising the platform, visually inspect the
oil lubricator sight gauge.
Result: There should be a maximum of 1 to 2
drops of oil visible in the sight gauge.
2 To adjust the drip rate, turn the oil flow control
valve clockwise to decrease the flow or
counterclockwise to increase the flow.
3 Repeat this procedure until the proper oil drip
rate is achieved.
Check the Air Filter/Regulator
Canister - Air Models
It is essential to drain the air filter/regulator canister
of water to ensure good air motor performance and
service life. A water-filled canister could cause the
air motor to perform poorly and continued use
could cause component damage.
1 Check the air filter/regulator canister for any
water accumulation.
2 If water is visible, loosen the drain plug at the
bottom of the canister and allow the water to
drain out.
3 Tighten the drain plug.
Scheduled Maintenance
Maintenance performed quarterly, annually and
every two years must be completed by a person
trained and qualified to perform maintenance on
this machine according to the procedures found in
the service manual for this machine.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before they are put back into service.