Owner's Manual

If connection is to be made through a take up reel cord: NON-MONITORED EDGE ONLY.
WARNING:
Actuating the operator using constant contact on the CLOSE
button will override external reversing devices, including sensing edges or
reversing edges.
SENSING EDGE SWITCH
N-O
REVERSE
N-O
REVERSE
CONTROL SIGNA
TERMINAL STRIP
Figure 9B
NOTE
: Monitored 2-wire
sensing or reversing
edge can
Figure 9A
NOTE: Do not connect
a 2-wire monitored
semsing edge switch
to these termiinals.
only be used
in combination with a
Timer-Close Module.
Figure 10
SENSING EDGE SWITCH
TIMER-CLOSE MODULE
TERMINAL STRIP
GND
MON
EDGE
VER VER
TERM NAL STR P
Figure 10 shows an example of a typical sensing edge installation. Left hand side is shown but
right hand is a mirror image of this.
1A) If wiring from sensing edge switch to operator is coiled cord or 2 wire jacketed cord:
Install junction box 12” above the center of the door opening on same side as
sensing switch.
Secure one end of cord to junction box using a cable clamp.
1B)
Install on same side as sensing edge switch and above door opening and
slightly to the side.
Install junction box adjacent to take up reel and route the stationary cord from
the reel to the box and secure with a cable clamp.
2) Secure other end of cord (straight, coiled or reel) to sensing edge switch
enclosure using a cable clamp.
3) Connect wires of cord to sensing edge switch using wire nuts or other suitable
wire connectors.
4) Run a straight 2 wire cord from the junction box to the operator electrical box.
Secure using cable clamp on each end.
5) Join wires in cord fro
m operator to wires in cord from switch using wire nuts or
other suitable wire connectors.
9A)
9B)
Non-Monitored sensing or reversing edge connects to terminal strip using N-O
Safety inputs. See Fig. 9A .
9C)
Monitored sensing or reversing edge connects to Timer-Close Module terminals as
shown in Fig. 9B .
Monitored sensing or reversing edge (no monitored Safety-T-Beam®) using the
Monitored Edge Interface Module (OPAKMEIGX.S) connects to ODC STB terminals as
shown in Fig. 9C .
7) Operate the door to make certain cord is free to travel and does not become
snared during door opening or closing.
Check sensing edge switch for proper operation.
Sensing Edge Switch Installation
5.6
NOTE: Monitored
sensing edge connects
to main circuit board
ODC STB terminals using
optional OPAKMEIGX.S
INTERFACE MODULE.
ODC
STB
ODC
STB
SENSING EDGE SWITCH
INTERFACE
MODULE
MAIN CIRCUIT BOARD
Figure 9C
www.geniecompany.com 08-12
Counter Door Operator
GCL-GCX