Owner's Manual

OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
OPEN
CLOSE
STOP
CAL
RUN
SCROLL
SCROLL
SET
CLEAR
Section 8: Troubleshooting
These operators display their status on the integrated display. Each time the operator
runs, stops, reverses or refuses to run, the display will indicate why the action did, or did
not, take place.
Once an error code has been generated, the operator will continue to display the
error code while the operator is not running. This error code can be cleared by pressing
the STOP button or STOP key on the keypad. The error code will automatically clear
when the operator stops at the down limit. Error codes will continue to be stored in the
operator’s Error Code Memory after they have been cleared from the display in the
Run Mode.
Display Operation in Run Mode
To aid in troubleshooting problems, these operators include an error code memory that
stores the last 10 error events. These codes are stored with or without power. The last
error code detected is also displayed on the LCD until the stop button or key is pressed
or the operator stops at the down limit.
The error code memory stores the last 10 error codes in sequence. Once 10 codes are
stored, the oldest code
is erased to make room for the newest code. These codes are
displayed in calibration mode. The display will flash the number of the error code and
the 2-digit error code followed by a description of the error code. Fig. 1 & 2.
Error Codes
ERROR CODE 1 41
Figure 1
REV ONE BUTTON
Figure 2
3.18.1
www.geniecompany.com 08-12
Counter Door Operator
GCL-GCX