Specification

S 1 2 0 9
S E R I E S
551-0001-02
Important Notice:
These materials have been prepared by Gentex Corporation ("Gentex") for informational purposes only, are
necessarily summary, and are not purported to serve as legal advice and should not be used as such.
Gentex makes no representations and warranties, express or implied, that these materials are complete and
accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules.
The materials do not address all legal considerations as there is inevitable uncertainty regarding
interpretation of laws, regulations and rules and the application of such laws, regulations and rules to
particular fact patterns. Each person's activities can differently affect the obligations that exist under
applicable laws, regulations or rules. Therefore, these materials should be used only for informational
purposes and should not be used as a substitute for seeking professional legal advice. Gentex will not be
responsible for any action or failure to act in reliance upon the information contained in this material.
24 units per carton
24 pounds per carton
V
AC
ELECTRICAL
BOX
QUICK DISCONNECT
T
YPE PLUG
HOT / BLACK
NEUTRAL / WHITE
TANDEM WIRE
BRN / YEL
ELECTRICAL
BOX
ELECTRICAL
BOX
T
ANDEM WIRE
B
RN / YEL
(LEGACY)
Wiring Diagrams
LIMITATIONS:
M
aximum of 12 S1209 smoke alarms may
be connected together. Do not exceed 125
feet (38.1 m) between each alarm. Do not
e
xceed 1125 feet (342.9 m )between the
first and last alarm.
NNOOTTIICCEE::
GGeenntteexx ssmmookkee aallaarrmmss CCAANN NNOOTT
bbee iinntteerrccoonnnneecctteedd ttoo aallaarrmmss ffrroomm ootthheerr
m
m
a
a
n
n
u
u
f
f
a
a
c
c
t
t
u
u
r
r
e
e
r
r
s
s
.
.
A
MAXIMUM OF 12 ALARMS WITH A
RELAY (S1209F) MAY BE TANDEM
INTERCONNECTED.
The S1209 may be tandem interconnected
with other Gentex tandem capable smoke
alarms, CO alarms or smoke/CO alarms.
To interconnect with Gentex 9000 Series,
7000 Series, 710CS Series, 7109CS
Series, GN-200 Series & GN-300 Series
the LEGACY TANDEM WIRE must be
used. Refer to installation manual for
detailed information.
120 VOLTS
60Hz
TTOO AADDDDIITTIIOONNAALL
SSMMOOKKEE AALLAARRMMSS,,
CCOO AALLAARRMMSS OORR
SSMMOOKKEE//CCOO AALLAARRMMSS
CCAAUUTTIIOONN::
RED/YELLOW & BROWN/YELLOW wire to be
capped when not in use. This wire is for tandem connection
only. Do not connect to any other circuit.
BLK
WHT
RED/YEL
BRN/YEL
VIO
VIO/BLK
BLU
ORN
YEL
GRAY
GRAY
PPLLUUGG
SSMMOOKKEE
AALLAARRMM
HOT
NEUT
R
ED/YEL
BRN/YEL
POWER
TANDEM - LEGACY
TANDEM - NEW
FORM A
A
LARM CONTACTS
F
ORM C
ALARM CONTACTS
SUPERVISION
WIRES
Tandem Wiring Diagram
Relay Model Wiring Diagram
Architect & Engineering Specifications
The photoelectric smoke alarm shall be a Gentex Model S1209/S1209F or approved equal which shall provide at least the following features and functions:
1. Nominal smoke sensitivity shall be 2.5%.
2. The smoke alarm portion of device shall utilize an infrared LED sensing circuit which pulses in 4 to 5 second intervals when subjected to smoke. After 2 consecutive
pulses in smoke, the alarm will activate.
3. The S1209 Series alarm shall have a Duracell
®
MN 1604 9VDC alkaline battery as a back-up in the event building power is lost.
4. The 9VDC battery impedance shall be verified by the circuit of the smoke alarm.
5. The alarm shall provide an indicator when the battery is low in power, high impedance or is missing.
6. A solid state piezo alarm meets or exceeds the rating of 85dBA at 10ft.
7. A visual LED monitor (condition indicator) will slow pulse in normal operation and rapid pulse in alarm (red color)
8. An easily accessible test button shall be provided. Push down on button for 5 seconds causing smoke alarm to activate. If device does not go into alarm, the device
is not working properly.
9. The device shall have tandem interconnect capability of up to 12 smoke alarms.
10. The alarm shall have the capability to tandem interconnect with all Gentex tandem capable smoke alarms, CO alarms or combination smoke/CO alarms,including
7000/7003 Series, 9000/9003 Series, 710CS/713CS Series, 7109CS/7139CS Series, GN-200/GN-300 Series, CO1209 Series and GN-503 Series
11. The manufacturer shall provide models with the optional feature of auxiliary Form A/Form C relay contacts for initiating remote functions and annunciation
12. Unit must be ANSI/UL 217 listed for both wall and ceiling mounting.
13. Unit shall be listed by Underwriters Laboratories and California State Fire Marshal (CSFM).
All equipment shall be completely factory assembled, wired and tested, and the contractor shall be prepared to submit a certified letter
testifying to this condition. Alarms which do not meet all of the requirements of this specification will not be considered.
For complete product specifications, refer to product installation manual.
NOTES:
Utilizing
DUALINK
®
,
if S1209 alarm annunciates, all smoke alarms, CO alarms or combination smoke/CO alarms tandem interconnected will sound
smoke alarm warning.
Utilizing
DUALINK
®
,
if S1209 is tandem interconnected with CO alarms or combination smoke/CO alarms and CO devices go into alarm, CO alarms
and smoke alarm will sound CO warning.
When both smoke and CO conditions are present, smoke condition will have priority and alarm will sound smoke annunciation.
SSMMOOKKEE
AALLAARRMM
(
(
L
L
E
E
G
G
A
A
C
C
Y
Y
)
)
SSMMOOKKEE
AALLAARRMM
SSMMOOKKEE
AALLAARRMM