28EZiSYSTEM, How to Use the Locator
Activating line depth will provide an inaccurate readout.
Mark utilities with marker paint, pegs, flags or similar. Never drive pegs into the ground
over the service.
Additional services may be within the excavation zone, as well as the service you are
taking a depth reading from.
An additional depth reading should be taken with the locator lifted off the ground by
approximately 100 mm (4 inches). The reading obtained should confirm the addition of
this height.
Depth shown and diameter:
Warning The depth reading may not indicate the real depth of the service, especially if the sonde is
lying at the base of a large diameter duct.
Precautions:
Always compensate depth reading for service size.
Take special care when the signal is produced
by a sonde, lying in a large diameter conduit!