User Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- Garantie limitée, limites de responsabilité et restrictions
- FCC Notice (for U.S. Customers):
- (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination.
- Or
- Frequency Coordination Branch, OET
- ATTN: UWB Coordination
- Canadian Requirements for RSS-220
- Canadian Requirements of RSS-220 for Ground Antennas
- Canadian Requirements of RSS-220 for Hand-held Antennas
- Canadian Requirements of RSS-220 for Search and Rescue Antennas
- Table of Contents
- Section 1: Introduction 1
- StructureScan™ Mini XT 2
- Section 2: Getting Started 3
- Section 3: Using ScanEZ Mode 5
- Section 4: Using the Scan3D App 10
- Section 5: Using the ScanMax App 14
- Section 6: Calibrating for Depth in the ScanMax App 20
- Section 7: Using the DualScan App 23
- Section 8: File Management 26
- Setting up Your Laptop/PC and Data Transfer 27
- Launching and Navigating the Software 28
- Viewing and Processing the Data 30
- Processing the Data 32
- Ribbon Options 34
- Home Ribbon Options 34
- 3D Volume Options Ribbon 40
- Chapter 1: Using the StructureScan Mini XT
- Section 1: Introduction
- StructureScan™ Mini XT
- Section 2: Getting Started
- Section 3: Using ScanEZ Mode
- Section 4: Using the Scan3D App
- Section 5: Using the ScanMax App
- Section 6: Calibrating for Depth in the ScanMax App
- Section 7: Using the DualScan App
- Section 8: File Management
- Chapter 2: Using RADAN for StructureScan Mini
- Setting up Your Laptop/PC and Data Transfer
- Launching and Navigating the Software
- Viewing and Processing the Data
- Processing the Data
- Ribbon Options
- Home Ribbon Options
- 3D Volume Options Ribbon
- Appendix A: The Dielectric Constant
- Appendix B: Data Interpretation and Examples of Common Features
- Appendix C: Technical Specifications
- Appendix D: Accessories
- Appendix E: Labeling
Geophysical Survey Systems, Inc. StructureScan™ Mini XT
Manual
MN 70-813 Rev C 11
Collecting a Grid
1 Position the Mini XT on the first line in the
“X” direction on the scan template. Take care
that the side lasers are lined up on the thick,
black start line and that the front laser is
aligned with the line you are scanning.
2 Using the handle keypad, click the arrow in the
direction of Scan. The Mini XT will switch to
the collection screen and you will see an
overview of the grid template. Pull the handle
trigger to start the Mini XT recording. Wait for
the Mini XT to beep before moving.
3 Roll the Mini XT in a straight line to the end of
the scan pad to just beyond the edge of the printed grid. The Mini XT will beep twice and stop
recording when it receives enough data.
4 Pick up the Mini XT and position it at the beginning of the next line. Pull the handle trigger to start
the Mini XT recording. Wait for the Mini XT to beep before moving.
5 When you are finished with the final “X” direction line, move on to the “Y” direction and continue
the process until you have collected all of the lines.
6 Select Close Grid from the Menu Carousel when finished.
• You will see the screen below while you are collecting a grid. The bar at the top will display the
current line and axis. Take note of the data display. Features in the concrete will begin to show and
may help to identify any positioning errors so that you can recollect a line before finishing the grid.
• If you need to redo a line, finish the
current line and select Previous
Line from the menu carousel. You
can then collect that line as normal
and it will overwrite the earlier
version of that line.
Lasers properly aligned