User Manual
Table Of Contents
- Limited Warranty, Limitations Of Liability And Restrictions
- Garantie limitée, limites de responsabilité et restrictions
- FCC Notice (for U.S. Customers):
- (a) UWB imaging systems require coordination through the FCC before the equipment may be used. The operator shall comply with any constraints on equipment usage resulting from this coordination.
- Or
- Frequency Coordination Branch, OET
- ATTN: UWB Coordination
- Canadian Requirements for RSS-220
- Canadian Requirements of RSS-220 for Ground Antennas
- Canadian Requirements of RSS-220 for Hand-held Antennas
- Canadian Requirements of RSS-220 for Search and Rescue Antennas
- Table of Contents
- Section 1: Introduction 1
- StructureScan™ Mini XT 2
- Section 2: Getting Started 3
- Section 3: Using ScanEZ Mode 5
- Section 4: Using the Scan3D App 10
- Section 5: Using the ScanMax App 14
- Section 6: Calibrating for Depth in the ScanMax App 20
- Section 7: Using the DualScan App 23
- Section 8: File Management 26
- Setting up Your Laptop/PC and Data Transfer 27
- Launching and Navigating the Software 28
- Viewing and Processing the Data 30
- Processing the Data 32
- Ribbon Options 34
- Home Ribbon Options 34
- 3D Volume Options Ribbon 40
- Chapter 1: Using the StructureScan Mini XT
- Section 1: Introduction
- StructureScan™ Mini XT
- Section 2: Getting Started
- Section 3: Using ScanEZ Mode
- Section 4: Using the Scan3D App
- Section 5: Using the ScanMax App
- Section 6: Calibrating for Depth in the ScanMax App
- Section 7: Using the DualScan App
- Section 8: File Management
- Chapter 2: Using RADAN for StructureScan Mini
- Setting up Your Laptop/PC and Data Transfer
- Launching and Navigating the Software
- Viewing and Processing the Data
- Processing the Data
- Ribbon Options
- Home Ribbon Options
- 3D Volume Options Ribbon
- Appendix A: The Dielectric Constant
- Appendix B: Data Interpretation and Examples of Common Features
- Appendix C: Technical Specifications
- Appendix D: Accessories
- Appendix E: Labeling
Geophysical Survey Systems, Inc. StructureScan™ Mini XT
Manual
MN 70-813 Rev C 14
Section 5: Using the ScanMax App
ScanMax is a 2D data collection program. You will have much greater control over data collection
parameters, gain, and filtering in ScanMax than in ScanEZ. Please note that ScanMax is accessible only
when in the Standard or Advanced UI setting.
When using ScanMax for the first time, you may want to set some overall, global settings in the menu
carousel.
On the primary (top) level of the menu carousel, you will have the following options to set:
• Project: Choose one of six project folders in which to store your data. This will help to keep files
organized. Note that files collected in one project will not be visible when the Mini XT is set to a
different project.
• Scan Density: Set the number of scans per inch (cm). Normal = 10/in (4/cm) and
High = 20/in (8/cm).
• Select Language: Choose your desired language.
• Units: Choose from Metric or English (Imperial).
• Clear Storage: Erase all data stored on the Mini XT in all project folders at once.
• Version Control: Allows you to see your current software and firmware versions. This is also
where you will go to update software/firmware. See Appendix C for more instructions on updating
your Mini XT.
• Calibrate Antenna: This will calibrate your Mini XT’s system gain and antenna surface position.
GSSI recommends that you periodically re-calibrate your Mini XT.
In the secondary (bottom) level of the carousel, you will have the following options:
• Save Prompt: Turning this “On” will cause the Mini XT to ask at the end of each file if
you want to save. The Mini XT will save each file automatically if this option is set to “Off.”
• Backlight: Change the screen brightness in 25% increments.
Menu
Carousel