Owner manual

Estimating Drywall Nails
WALLWORKSGUIDE
Planning, Applying, Installing, Finishing
and Repairing Your Walls and Ceilings.
PAGE
1 of 8
PLAN
Sketch
A little planning before the job begins can save you a lot
of time and materials later on.
Sketch out the area you want to cover with DensArmor
Plus
®
panels. Use the sketch as a guide to determine
how much drywall you’ll need.
Remember to plan for the board to be installed across
(perpendicular to) joists and/or studs.
Try to avoid end joints wherever possible. To do that,
you may want to buy 128 (3658 mm) instead of 88
(2438 mm) board, depending on your room size.
If end joints can’t be avoided, stagger them so they all
don’t fall at one end of the room.
Your DensArmor Plus panels should be stored flat, indoors,
and away from moisture and temperature extremes,
until you’re ready to use it. As soon as possible after
joint treatment is thoroughly dry, all surfaces should be
sealed or primed.
Estimate
Once you’ve determined how much DensArmor Plus
panels you’ll need, you can use the following charts to
estimate for nails, joint compound and tape.
Note: If you’re applying drywall to masonry walls,
see ‘‘Masonry’’ section for additional materials.
*How Much Board Do You Need?
First, figure out the wall and ceiling areas:
Ceiling area = Width of the room x Length of the room
Wall area = (Width + Length) x 2 x Height of the room
For example, a 128 (3658 mm) x 168 (4877 mm) x 88 (2438 mm)
room has a wall/ceiling area of 640 sq. ft. (59.5 m
2
)
Ceiling area: 12 x 16 = 192
Wall area: (12 + 16) x 2 x 8 = 448; 192 + 448 = 640.
Look at the Room Measurement Table for a quick
reference. Measure door and windows area and subtract
their square footage from the total square footage to
obtain net room area.
Then refer to the Panel Coverage Table to locate the
number of wallboard panels required for the room. Be
sure to allow 10% to 15% overage for cutting and piecing.
Panel Coverage Table (in sq. ft. of wall area)
1 2 3 4 5 6
Panel Panels Panels Panels Panels Panels
4* x 8* Panel 32 64 96 128 160 192
4* x 9* Panel 36 72 108 144 180 216
4* x 10* Panel 40 80 120 160 200 240
4* x 12* Panel 48 96 144 192 240 288
4* x 14* Panel 56 112 168 224 280 336
4* x 16* Panel 64 128 192 256 320 384
48 58 68 78 88 98 108 118 128 138 148 158 168
88 224 248 272 296 320 334 368 392 416 440 464 488 512
98 244 269 294 319 344 369 394 419 444 469 494 519 544
108 264 290 316 342 368 394 420 446 472 498 524 550 576
118 284 311 338 365 392 419 446 473 500 527 554 581 608
128 304 332 360 388 416 444 472 500 528 556 584 612 640
138 324 353 382 411 440 469 498 527 556 585 614 643 672
148 344 374 404 434 464 494 524 554 584 614 644 674 704
158 364 395 426 457 488 519 550 581 612 643 674 705 736
168 384 416 448 480 512 544 576 608 640 672 704 736 768
Room Measurement Table*
(in. sq. ft. of wall and ceiling area)
Joist/Stud DensArmor Approx. lbs. of
width Plus
®
Drywall nails per 1000 sq. ft.
(on center) Thickness Nails of drywall
169
1
29 1
5
89 coated 5
1
4 lbs.
249
5
89 1
7
89 coated 5
1
4 lbs.
Panel Sq. Ft. Joint Compound Tape
100-200 sq. ft. 12 lb. Pail two 608 rolls
500 sq. ft. 48 lb. Ctn. one 2508 roll
800 sq. ft. 61.7 lb. Pail two 2508 rolls
Estimating Joint Compound and Tape
48( wide DensArmor Plus; 8* high framing
48(
48(