User Manual
Table Of Contents
- Contents
- Note for Users Upgrading GV-ASManager
- Firmware and Software Compatibility
- Naming and Definition
- Chapter 1 Introduction
- Chapter 2 Installation
- Chapter 3 The Main Screen of GV-ASManager
- Chapter 4 Settings
- Chapter 5 Video Integration
- Chapter 6 Anti-Passback
- Chapter 7 Patrol Tour
- Chapter 8 Other Functions
- 8.1 Setting Up System User
- 8.2 Setting Up Alert Notification
- 8.3 Startup, Backup and Export Setup
- 8.4 Setting Up GV-GF Fingerprint Readers
- 8.5 Scanning Driver’s Licenses and Business Card
- 8.6 Setting Hot Keys to Quickly Control Doors
- 8.7 Using Remote Lock Down App
- 8.8 Defining New Card Formats
- 8.9 Monitoring Emergency Exits with Input Sensors
- 8.10 Designing and Printing Access Card Template
- Chapter 9 GV-ASRemote
- Chapter 10 GV-ASWeb
- 10.1 Connecting to GV-ASManager
- 10.2 Accessing Live Video
- 10.3 Monitoring GV-ASManager
- 10.4 Accessing Logs
- 10.5 Adding and Deleting Controllers / LPR
- 10.6 Adding and Deleting Cards and Users
- 10.7 Searching, Adding and Deleting IP Cameras
- 10.8 Setting Schedule
- 10.9 Setting Access Groups
- 10.10 Setting Door Groups
- 10.11 Configuring Areas for Anti-Passback
- 10.12 Creating Maps
- 10.13 Setting Export Schedule for Lists and Logs
- 10.14 Setting Up Other Functions
- 10.15 Creating Accounts to Manage GV-ASWeb
- 10.16 Accessing GV-ASWeb using Mobile Devices
- Chapter 11 GV-TAWeb for Workforce Schedule and Payroll
- Chapter 12 GV-VMWeb for Visitor Management
- Chapter 13 License Plate Recognition
- Chapter 14 GV-Access Mobile Applications
- Chapter 15 GV-ASNotify
- Chapter 16 Database Settings
- Chapter 17 Net Module Utility
- Chapter 18 Troubleshooting
- Appendix
28
Lock Reset Time: If the door is monitored, type the number of seconds the door can
be held open. After the specified time expired, the door will automatically be locked.
Next to Handicap Card, type the number of seconds the door will be held open
when a Handicap Card is swiped.
Held Open Time: If the door is monitored, type the number of seconds the door can
be held open before a Door Held Open alarm is generated. Next to Handicap Card,
type the number of seconds the door can be held open after a Handicap Card is
swiped before a Door Held Open alarm is generated.
Lock Card Time: The user will be denied access if he or she tries to re-access the
door more than 1 time within the specified Lock Card Time. For example, if the Lock
Card Time of a cafeteria entrance is set to 7200 seconds, someone who entered the
cafeteria at 9 am will be prevented from re-entering the cafeteria until 11 am.
Fire Action: Set the door to be locked or unlocked when fire alarm occurs.
3. The following settings are OPTIONAL and are only applicable when related settings are
also configured:
Reader’s Keypad: When the Card and PIN Code Mode is applied, normally both the
access card and PIN code are required. But if the Entrance or Exit option is not
selected, only the access card is required to unlock the door. For example, if only the
Entrance option is selected, the user will be required to both present the card and
enter the PIN code to unlock the entry door, but only the card will be required to
unlock the exit door. To apply Card and PIN Code mode, see step 6 below.
Anti-Passback: For detailed instructions, see Chapter 6 Anti-Passback.
Auto Check Out: Automatically checks out the Visitor Card when the visitor
presents the card at the exit door. To set a card as Visitor Card, see Adding a Single
Card section later in this chapter.
Two Person Rule: Select Entrance to require presenting Two Person A Card and
then Two Person B Card before the entry door is unlocked. Select Exit to require
presenting both cards in the right order before the exit door is unlocked. To set a
card as Two Person A/B Card, see Adding a Single Card section later in this chapter.
GeoFinger: Allow GV-ASManager to upload enrolled fingerprints to the specified
fingerprint reader. Refer to Chapter 3 Fingerprint Only Mode in the GV-GF
Fingerprint Reader User’s Manual for details.