User Manual

Table Of Contents
Settings
29
4
Interlock: Enable Interlock function on the selected doors. Doors that are
interlocked cannot be open at the same time. The door only unlocks when the other
door is closed. Using Figure 4-4 as an example, Door 1 will not unlock if either of
Doors 3 and 4 is open, and when Door 1 is open, Doors 3 and 4 will not unlock. The
Interlock function is not available for GV-EV48.
Time Clock: This option must be selected to enable GV-TAWeb. See Chapter 11
GV-TAWeb for Workforce Schedule for more details.
4. The settings in the Alarm Event section are OPTIONAL unless an alarm device is
installed on the GV-AS Controller. Enable the desired alarm conditions that will cause the
alarm to occur: Held Open, Force Open, Tamper, Fire Alarm, Access Denied,
Tailgating and Urgent Code entered.
Alarm Continuous Time: Type the duration of the alarm sounds in seconds for
Access Denied alarm.
5. The settings in the Camera Mapping section are OPTIONAL unless a camera is installed
at the secure site. For details, see Chapter 5 Video Integration.
6. The Authentication Schedule is an OPTIONAL setting for specifying different access
modes at different periods of time. The default access mode is Card Mode that requires
users to present the card only to be granted access. You can click the finger button
to apply the settings to all doors.
Figure 4-5
To define which kind of access mode should be applied at specific day and time, select
one access mode on the toolbar and drag the mouse over the timelines. Four (4) access
modes are available in the system: