User Manual

Table Of Contents
38
Clear Event: The user can clear alarm events by presenting the card. All alarms
in the Device View window are erased. A record of these alarms is still kept in the
Alarm Monitor.
Disable Lock Card / Allow Access during Lockdown Mode: When the option is
selected, the card will be exempt from the Lock Card Time setting. In addition, this
card will be allowed access to doors when Lockdown Mode is activated.
For details on Lock Card Time, refer to Step 2: Configuring the Doors or Elevator
Floors in Chapter 4. For details on Lockdown Mode, refer to the Device View section
in Chapter 3.
Note: The Allow Access during Lockdown Mode function only works with:
z GV-AS210 / 2110 / 410 / 4110 / 810 / 8110 with firmware V1.23 or later
z GV-AS2120 with firmware V1.35 or later
z GV-AS1010 / 1110 with firmware V1.0 or later
Access Group: Access Groups control which personnel can access which door and
at what time. For details, see 4.5 Setting Access Groups.
For first-time user of the GV-ASManager, the access group is not yet established.
Select User Define for test run.
Controller: The Controller column displays the associated doors. The selection for
each door will be automatically brought up when one access group was entered.
For first-time user of the GV-ASManager, select 24-hour access for each door for
test run.
Data Group: Assign the card to a data group or select No Groups to disable the
data group function. You can then allow or forbid a user to read/write/execute the
functions listed under the data group. Refer to Adding a New User in Chapter 8 for
more details.
4. Present the enrolled card to the reader. Once the card has been accepted, the message
Access Granted will be displayed.
Note: GV-AS200 only supports the first 10,000 cards. All other controllers can support up to
40,000 cards.