User Manual

Table Of Contents
any selected input is triggered.
With Camera(s): Sends the camera video to Center V2 when the
selected input is triggered. Click the Set Camera(s) button to assign
cameras for the application.
Event Type: If the subscriber wants Center V2 always to get notified
of the input trigger, select Emergency. If the subscriber wants Center
V2 to get notified of the input trigger only when an assigned input is
triggered, select Normal.
Right Arrow button: Sets the delay time to notify Center V2 of input
trigger. This feature is only available when the Normal type is chosen.
Exit Delay: While the system is activated, this feature provides
an interval of time for the subscriber to exit the premises.
During this time, the specified input (e.g. an exit/entry door) is
inactive. Once the exit delay expires, the input will be fully
armed.
Entry Delay: While the system is activated, this feature
provides an interval of time for the subscriber to entry the
premises. During this time, the specified input (e.g. an
exit/entry door) is inactive so that the subscriber can disarm the
system. If the subscriber fails to do, once the entry delay
expires, Center V2 will get notified of the input trigger.
Output Module: Enables the assigned output module when the
selected input module is triggered.
For the example of Figure 1-14, when the I/O Device (Module 1, Input
4) is triggered, the Output (Module 1, Pin 3) will be activated
simultaneously.
Right Arrow button: Sets the delay time to trigger the assigned
output module.
Event Type: If the subscriber wants Center V2 always to get notified
of the output trigger, select Emergency. If the subscriber wants
Center V2 to get notified of the output trigger only when an assigned
input is triggered, select Normal.
30