User Manual
Table Of Contents
- Important Notes
- Contents
- Chapter 2
- Chapter 3
- Video Analysis
- 3.1 Object Counting and Intrusion Alarm
- 3.2 Object Index
- 3.3 Automatic Video Snapshots
- 3.4 Face Detection
- 3.5 Face Count
- 3.6 Privacy Mask Protection
- 3.7 Panorama View
- 3.8 Video Defogging
- 3.9 Video Stabilization
- 3.10 Wide Angle Lens Dewarping
- 3.11 Advanced Motion Detection
- 3.12 Crowd Detection
- 3.13 Advanced Scene Change Detection
- 3.14 Advanced Unattended Object Detection
- 3.15 Advanced Missing Object Detection
- 3.16 Text Overlay
- 3.17 Fisheye View
- 3.18 Specifications
- Video Analysis
- Chapter 4
- Chapter 5
- Chapter 6
- Chapter 7
- Chapter 8
- Chapter 9
- Useful Utilities
- 9.1 Dynamic DNS
- 9.2 Watermark Viewer
- 9.3 Windows Lockup
- 9.4 Authentication Server
- 9.5 Fast Backup and Restore
- 9.6 Bandwidth Control Application
- 9.7 Language Setting
- 9.8 Skype Video Utility
- 9.9 GV-SDSyncCard Utility
- Useful Utilities
Video Analysis
3
Invoke Alarm: Enables the computer alarm when an object is detected to be missing. Click
the […] button next to the option to assign a .wav sound file.
Output Module: Enables the output device when an object is detected to be missing. Select
this option and use the drop-down list to assign an installed output module and a pin number.
Never Recycle: With the option selected, the event files of missing object detection will not
be recycled when the recycle threshold is reached.
8. You can click Test to test your settings. When the defined object is missing, a flashing box will
appear on its location for warning. If the missing object cannot be detected, increase Sensitivity
value to increase system sensitivity to changes in the camera view.
9. Click OK to apply the settings.
10. Start monitoring to run the application.
When any object, which you have outlined the regions for, disappears from the camera view for the
specified time, its location will be highlighted in live view, the selected alarm or output will be activated,
and the event will be recorded as Advanced Missing Object Detection in System Log for later
retrieval.
To manually stop all triggered alerts, click the Tools button
on the triggered channel, select
Reset Alert and select Advanced Missing Object Detection.
Reset Alert: Disables and resets the triggered alert. After the alert is reset if the object remains
missing over the specified tolerance time, the system will still detect it as a missing object and
keep generating alert.
Note: Optionally create a schedule for Advanced Missing Object Detection to be enabled at certain
times only. For details, see Creating Schedules in Chapter 1.