7.3.5 I/O Control
The I/O control panel shows the I/O status and alarm event. Additionally, you can force output, as well
as enable and disable I/O devices to the remote GV-VMS. Click the I/O Control button at the right of
the live view to bring out the I/O control panel.
I/O Control Panel
Single
View
Viewer
Figure 7-24 I/O Control
The alarm status is shows the triggered inputs. Clicking the Reset button will clear the alarm list.
To force trigger an output device, click the Enable button, highlight an output and then click the Output
button. The Timer functions the same as in the PTZ control panel. Each user will be given 60 seconds
of control time while the supervisor has 999 seconds. Clicking the Stop button will stop the operation
and turn over the control privilege to the next user waiting online.
If you want to enable or disable I/O devices to the remote GV-VMS, click the Enable/Disable I/O
button. Note that the Enable Remote Control option must be enabled in the WebCam Server Setup
dialog box (Figure 7-4)