User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
96
5.2 Installation
5.2.1 Connecting Card Readers
GV-AS410 / 4110 / 810 / 8110 supports two types of card reader interfaces:
• Wiegand: Compatible with any Wiegand card readers of 26 to 64 bits.
• RS-485: Only compatible with all GV-Readers and GV-GF Fingerprint Readers.
5.2.1.A Wiegand Readers
GV-AS410 / 4110 / 810 / 8110 provides 8 Wiegand inputs (Wiegand A to Wiegand H).
Connect up to 8 Wiegand readers ranging from 26 to 64 bits to the Wiegand interfaces.
Please consult the documentation of your Wiegand reader for wiring.
12V
D0
D1
GND
12V
D0
D1
GND
12V
D0
D1
GND
12V
D0
D1
GND
12V
D0
D1
GND
12V
D0
D1
GND
12V
D0
D1
GND
12V
D0
D1
GND
Figure 5-2
Note: Although 8 Wiegand inputs are available, GV-AS410 / 4110 only supports control of
up to 4 doors.