User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
116
6.2.2 Connecting Output Relay
Up to 24 output relays can be connected to the GV-EV48-24 Floors to control up to 24
elevator floors. Up to 48 output relays can be connected to the GV-EV48-48 Floors to control
up to 48 elevator floors. Each output relay is set to control access to a corresponding floor in
the elevator.
To connect output relay:
Connect the output relay on the GV-EV48 to the corresponding floor on the elevator control
panel. Next, connect the COM on the GV-EV48 to the COM on the elevator control panel.
COM
3/4
OUT4
OUT3
COM
7/8
OUT7
OUT8
COM
1/2
OUT2
OUT1
COM
5/6
OUT5
OUT6
COM
11/12
OUT12
OUT11
COM
15/16
OUT15
OUT16
COM
9/10
OUT10
OUT9
COM
13/14
OUT13
OUT14
IO Board
Connector
Elevator
Control Panel
1F
2F
3F
4F
COM
Figure 6-3