User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
xiv
Installation Considerations
1. There are distance limitations for Wiegand and RS-485 communications. Please note:
• Wiegand interface:
Recommended Wiegand cable: Wiegand cable (a twisted pair of 24 AWG wires)
100 meters (328.1 feet) for GV-AS2110 / 2120 / 4110 / 8110
30 meters (98.43 feet) for other GV-AS Controllers
• RS-485 interface: 600 meters (1968.50 feet)
Recommended RS-485 cable: standard 485 cable (a twisted pair of 24 AWG wires)
2. GV-ASManager software is used to manage GV-AS / GV-EV Controllers. There is a limit
for the number of controllers connected to GV-ASManager based on communication modes.
• Through network connection, up to 1000 GV-AS / GV-EV Controllers can connect to
GV-ASManager.
• Through RS-485 connection, up to 16 GV-AS100 / 110 / 120 Controllers can connect
to the same COM port on a computer running GV-ASManager.
3. When presenting cards to GeoVision readers and the built-in readers of GV-AS100 / 1010
/ 110 / 1110 / 120, make sure only one card is presented at a time to avoid frequency
interference.
Note:
1. For RS-485 connection between GV-AS Controllers and readers, user additional
power for the readers when the distance ranges from 30.48 ~ 600 meters (100 ~
1968.50 ft). There is no need to use additional power when the distance is within
30.48 meters (100 ft).
2. For GV-AS100 / 2110 / 2120 / 4110 / 8110, it is highly recommended to replace the
button cell battery included on the circuit board annually.