User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
160
8.2.7.B Output Condition Settings
This section explains the output functions available when Output Type is set to Normal,
Toggle or Pulse.
Figure 8-22
There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions
are Door/Gate/Relay conditions and 2 conditions are Input/Reader conditions. Each
condition is related to each other through AND/OR. AND means that all conditions with AND
must be triggered before the output is triggered. OR means that only 1 of the condition with
OR is needed to be triggered before the output is triggered. It is also valid to have certain
conditions as AND and certain conditions as OR.
For Pulse output type, the output is triggered for the amount of time set in the Sec field
(seconds).