User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
The Web Interface
165
8
Figure 8-25
[GV-Reader / CR420 / GF1921 / 1922 Function] Define the readers connected to the
controller, and then use the Function drop-down list to select the door associated with the
reader.
• GV-RK1352 / R1352 / DFR1352: Select the RS-485 checkbox and type the Serial
Number of the reader. Note that the ID number located next to the serial number field
need to match the reader’s ID number defined through the GV-RK1352 Config AP.
• GV-Reader 1251 / Reader 1352 V2: Select the RS-485 checkbox and leave the serial
number field blank. Note that the ID number located next to the serial number field need
to match the reader’s ID number defined by the dip switches on the reader.
• GV-GF1921 / GF1922: Type the MAC address of the fingerprint reader and do not
select the RS-485 checkbox.
• GV-CR420: Select the RS-485 checkbox only if the GV-CR420 is connected to the
controller through RS-485 connection. If the reader is using network connection, do not
check the RS485 box. Type the MAC address of GV-CR420 if you using the latest GV-
CR420 firmware. Refer to the note below if you are using firmware V1.0.