User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
204
Output Condition Settings:
When Output Type (No. 1, Figure 9-25) is set to be Normal, Toggle, Pulse, Normal
Lighting, Toggle Lighting or Pulse Lighting, the options similar to the figure below
become available.
Figure 9-27
There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions
are Door/Gate/Relay conditions and 2 conditions are Input conditions. Each condition is
related to each other through AND/OR. AND means that all conditions with AND must be
triggered before the output is triggered. OR means that only 1 of the condition with OR is
needed to be triggered before the output is triggered. It is also valid to have certain
conditions as AND and certain conditions as OR.
Only Output 5 ~ 8 can be connected to Lights. So Normal Lightning, Toggle Lighting and
Pulse Lighting can only be selected from Output 5 ~ 8. For Pulse and Pulse Lighting, the
output is triggered for the amount of time set in the Sec field (seconds).
2 x Door/Gate/Relay Conditions
2 x Input Conditions
Available in
Pulse/Lighting