User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
28
AS100 / 1010
Function
GV-ASBox: Enables or disables the connection to GV-ASBox /
GV-ASNet. (GV-AS100 only)
Control Type:
Door Entry Type: Sets GV-AS100 / 1010 as entry reader
of a door.
Door Exit Type: Sets GV-AS100 / 1010 as exit reader of a
door.
Parking Entry Type: Sets GV-AS100 / 1010 as entry
reader of a parking gate.
Parking Exit Type: Sets GV-AS100 / 1010 as exit reader
of a parking gate.
Elevator Type: GV-AS100 / 1010 reader is installed in the
elevator for access control.
Anti-Passback: Enables or disables the Anti-Passback
function.
Master PIN Change Changes the PIN code of the Master Card. (GV-AS100 only)
Enroll Pin Change Changes the PIN code of the Enroll Card. (GV-AS1010 only)
Delete Pin Change Changes the PIN code of the Delete Card. (GV-AS1010 only)
Local Rest Time Sets the time (1 to 255 sec.) that a door/gate remains open after
which the door will automatically be locked.
Set Held Open
Time
Sets the time (5 to 9999 sec.) that a door/gate can be held open
before an alarm is generated.
Set Alarm Event Enables or disables the alarm settings.
Set Fire Action Locks or unlocks the door/gate, or remains the current state when a
fire condition occurs.
Set Contact Type Sets the inputs to be normally open (NO) or normally closed (NC).
Set Function Key Define the function keys to indicate the start time or end time of the
attendance activities below (GV-AS1010 only): Work Time, Away,
Overtime, Break Time.
Note: The Parking Entry Type and Parking Exit Type only work when the sensor input of
Car Detection is activated. When the card is present but the sensor inputs are not activated,