User Manual

Table Of Contents
52
Set Alarm
Event
723_ _ _ _#
Held Open Î 0
Forced Open Î 1
Tamper Î 2
Fire Alarm Î 3
Access Denied Î 4
Alarm Time Î 1-10 sec
For the first blank digit, enter a number from
options 0 to 4. For the second blank digit, type 1
to enable the option and 0 to disable the option.
For the third and fourth blank digits, type the
number of seconds the alarm will sound.
For example, to enable the fire alarm for 3
seconds, press 7233103#
Door/Gate
Function
343_#
Door Entry TypeÎ0
Parking Entry TypeÎ1
Door Exit TypeÎ2
Parking Exit TypeÎ3
Elevator TypeÎ4
Door Entry Type: Sets GV-AS110 / 1110 as
entry reader of a door. The Wiegand reader
connected will be set as exit reader.
Parking Entry Type: Sets GV-AS110 / 1110
as entry reader of a parking gate.
Door Exit Type: Sets GV-AS110 / 1110 as
exit reader of a door. The Wiegand reader
connected will be set as entry reader.
Parking Exit Type: Sets GV-AS110 / 1110
as exit reader of a parking gate.
Elevator Type: GV-AS110 / 1110 reader is
installed in the elevator for access control.
For example, to set the GV-AS110 / 1110 as an
exit reader of a door, press 3432#.
Set
Authentication
Mode
526_#
Schedule ModeÎ0
Fixed Card ModeÎ1
Local Lock ModeÎ2
Local Unlock ModeÎ3
Fixed Card + PINÎ4
Fixed Card/CommonÎ5
Schedule Mode: Follows the authentication
schedule set on GV-ASManager.
Fixed Card Mode: Grants access after the
card is presented. Ignores the authentication
schedule of GV-ASManager.
Local Lock Mode: Remains locked. The
locked state cannot be cleared through GV-
ASManager.
Local Unlock Mode: Remains open. The
held-open state cannot be cleared through
GV-ASManager.
Fixed Card + PIN: Grants access after the
user presents the card and then enters the
card’s PIN code. Ignores the authentication
schedule of GV-ASManager.
Fixed Card/Common: Grants access after
card is presented or after the door’s
password is entered. Ignores the
authentication schedule of GV-ASManager.