User Manual
Table Of Contents
- Welcome
- Important Notes for Maintaining Power Supply
- Elevator Control
- Optional Devices
- Installation Considerations
- Firmware and Software Compatibility
- Definition
- 1. GV-AS100 / 1010 Controller
- 1.1 Introduction
- 1.2 Installation
- 1.3 Programming Mode
- 1.4 Web-Based Configurations
- 1.5 GV-AS100 / 1010 Specifications
- 2. GV-AS110 / 1110 Controller
- 3. GV-AS120 Controller
- 4. GV-AS210 / 2110 / 2120 Controller
- 5. GV-AS410 / 4110 / 810 / 8110 Controller
- 6. GV-EV48 Controller
- 7. Installing on a Network
- 8. The Web Interface
- 9. Optional Devices
- 9.1 Optional GV-ASBox
- 9.1.1 Main Features
- 9.1.2 Packing List
- 9.1.3 GV-ASBox Board Layout
- 9.1.4 Installation
- 9.1.5 GV-ASBox Specifications
- 9.2 Optional GV-ASNet
- 9.3 Web Interface through Optional Devices
- 9.1 Optional GV-ASBox
- 10. Troubleshooting
- Appendix
GV-AS120 Controller
67
3
To define ID number, control type and authentication mode
Using the GV-AS120 Setting AP in the GV-ASManager folder, you can define the ID
number of multiple GV-AS120 connected through RS-485 interface, as well as set the
control type and authentication mode.
1. Go to C:\Access Control\ASManager\ and double-click GV-AS120 SetupAP
V100.exe. This dialog box appears.
Figure 3-7
2. Select the COM port that is connected to GV-AS120 and click Open COM. The red
square should change to blue to indicate the COM port is correct.
Note: To verify the COM port that is connected to GV-AS120, go to Windows Device
Manager. In the Ports (COM & LPT) field, you should see the entry for Prolific USB-to-
Serial Comm Port. The COM port shown in parenthesis indicates the COM number
currently in use.
3. Select an ID number for the GV-AS120.
4. Use the drop-down list to define the Control Type and Authentication Mode. Refer to
Door / Gate Function and Set Authentication Mode in 2.3.2 Programming the GV-AS110
for more details on each type of Control Type and Authentication Mode.
5. Click Setup GO. The settings are sent to GV-AS120.