SPECIFICATIONS
5V CRIMP ROOFING PANELS
1. Code Approval numbers may have changed since publication. For the
most recent code approval numbers, contact Southeastern Metals’
Techincal Department or refer to the appropriate code agency.
SPACING AND FASTENING DETAIL
SIDELAP DETAIL
APPROVALS
Eave, Ridge & Valley · -93 psf = 12 in. O.C.
Field Fastening · -67.25 psf = 16 in. O.C.
26 Gauge
29 Gauge
Testing Data & Specifications
Accelerated testing 2000 hours - ASTM G23
Salt Spray testing 1000 hours - ASTM B117
Fire Testing - ASTM E108 or UL 790
Wind Driven Rain - TAS 100
Code Approvals
1
UL Fire Resistant Directory #R20735
Miami Dade NOA #: 16-0510.23 (26 ga. min.)
Florida Building #FL-11175 (29 ga. min.)
Anti-Siphon
Channel
State of
Florida
Approved
State of
Florida
Approved
25 ½ in. Overall · 24 in. Coverage
11 ½ in. 12 ½ in.
⁄ in.
Eave, Ridge & Valley · -180 psf · 8 in. O.C.