SM-Rib
35
Prole/Flashing
*
1:12 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12
Ridge Cap 135° 170° 161° 152° 143° 135° 127° 120° 113° 106° 100° 95° 90°
Hip Cap 148° 173° 166° 160° 154° 148° 143° 138° 133° 130° 126° 123° 120°
Pre-formed Valley 136° 172° 162° 152° 144° 136° 128° 120° 114° 108° 104° 98° 90°
High Side Ridge 67° 87° 81° 76° 71° 67° 63° 60° 56° 53° 50° 47° 45°
Eave Flashing 90° 94° 99° 104° 108° 112° 116° 120° 123° 126° 128° 132° 135°
End Wall Flashing 112° 94° 99° 104° 108° 112° 116° 120° 123° 126° 128° 132° 135°
Eave Drip 90° 94° 99° 104° 108° 112° 116° 120° 123° 126° 128° 132° 135°
Gambrel Flashing
To calculate the required pitch (X°), use the following equation:
180° - ( A° - B° ) = Gambrel Flashing pitch (X°)
Transition Flashing
To calculate the required pitch (X°), use the following equation:
180° - ( A° - B° ) = Transition Flashing pitch (X°)
A
B
X°
A
B
X°
Flashing Angle Specier Chart
* Default Pitch unless otherwise specied