SDS

Contents under pressure. Pressurized container may explode when exposed to heat or flame.
During fire, gases hazardous to health may be formed.
Specific hazards arising from
the chemical
Firefighters must use standard protective equipment including flame retardant coat, helmet with
face shield, gloves, rubber boots, and in enclosed spaces, SCBA.
Special protective equipment
and precautions for firefighters
In case of fire: Stop leak if safe to do so. Do not move cargo or vehicle if cargo has been exposed
to heat. Move containers from fire area if you can do so without risk. Containers should be cooled
with water to prevent vapor pressure build up. For massive fire in cargo area, use unmanned hose
holder or monitor nozzles, if possible. If not, withdraw and let fire burn out.
Fire fighting
equipment/instructions
Use standard firefighting procedures and consider the hazards of other involved materials. Move
containers from fire area if you can do so without risk. In the event of fire and/or explosion do not
breathe fumes.
Specific methods
Flammable aerosol. Contents under pressure. Pressurized container may explode when exposed
to heat or flame.
General fire hazards
6. Accidental release measures
Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Keep out of
low areas. Many gases are heavier than air and will spread along ground and collect in low or
confined areas (sewers, basements, tanks). Wear appropriate protective equipment and clothing
during clean-up. Do not breathe mist or vapor. Emergency personnel need self-contained
breathing equipment. Do not touch damaged containers or spilled material unless wearing
appropriate protective clothing. Ventilate closed spaces before entering them. Local authorities
should be advised if significant spillages cannot be contained. For personal protection, see section
8 of the SDS.
Personal precautions,
protective equipment and
emergency procedures
Refer to attached safety data sheets and/or instructions for use. Stop leak if you can do so without
risk. Move the cylinder to a safe and open area if the leak is irreparable. Isolate area until gas has
dispersed. Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area).
Keep combustibles (wood, paper, oil, etc.) away from spilled material. Prevent product from
entering drains. Cover with plastic sheet to prevent spreading. Absorb in vermiculite, dry sand or
earth and place into containers. Following product recovery, flush area with water.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to
remove residual contamination. For waste disposal, see section 13 of the SDS.
Methods and materials for
containment and cleaning up
Avoid release to the environment. Inform appropriate managerial or supervisory personnel of all
environmental releases. Prevent further leakage or spillage if safe to do so. Avoid discharge into
drains, water courses or onto the ground.
Environmental precautions
7. Handling and storage
Obtain special instructions before use. Do not handle until all safety precautions have been read
and understood. Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
Pressurized container: Do not pierce or burn, even after use. Do not use if spray button is missing
or defective. Do not spray on a naked flame or any other incandescent material. Do not smoke
while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or
expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when
handling the product must be grounded. Close valve after each use and when empty. Protect
cylinders from physical damage; do not drag, roll, slide, or drop. When moving cylinders, even for
short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Suck back of
water into the container must be prevented. Do not allow backfeed into the container. Purge air
from system before introducing gas. Use only properly specified equipment which is suitable for
this product, its supply pressure and temperature. Contact your gas supplier if in doubt. Do not
re-use empty containers. Do not breathe mist or vapor. Avoid contact with eyes, skin, and clothing.
Avoid prolonged exposure. When using, do not eat, drink or smoke. Pregnant or breastfeeding
women must not handle this product. Should be handled in closed systems, if possible. Use only in
well-ventilated areas. Wear appropriate personal protective equipment. Wash hands thoroughly
after handling. Avoid release to the environment. Observe good industrial hygiene practices.
Precautions for safe handling
Level 2 Aerosol.
Store locked up. Pressurized container. Protect from sunlight and do not expose to temperatures
exceeding 50°C/122 °F. Do not puncture, incinerate or crush. Do not handle or store near an open
flame, heat or other sources of ignition. This material can accumulate static charge which may
cause spark and become an ignition source. Cylinders should be stored upright, with valve
protection cap in place, and firmly secured to prevent falling or being knocked over. Stored
containers should be periodically checked for general condition and leakage. Store in a
well-ventilated place. Store away from incompatible materials (see Section 10 of the SDS).
Conditions for safe storage,
including any incompatibilities
3 / 14
Material name: ROYAL BROWN
10340 705172 406 Version #: 03 Revision date: 12-07-2018 Issue date: 04-15-2015
SDS US