Installation Instructions

101
Diagnostics
Gigaset N720 DECT IP Multicell System / engbt / A31008-M2314-L101-6-7619 / diagnose.fm / 29.08.2016
Version 2, 06.08.2010
Diagnostics
The web configurator for the DECT manager (£ S. 58) offers different tools for
monitoring the operation and diagnosis in the event of problems occurring.
System Log (SysLog)
Settings ¢ Management ¢ System Log
The system report (SysLog) gathers information about selected processes performed by
the DECT manager and base stations during operation and sends this to the configured
SysLog server. Activate the function if you wish to create an error ticket for Gigaset.
¤ Enter the IP address and Server port for storing the system log on a server (default
setting for the server port: 514).
¤ Mark the field by Activate syslog.
Setting the filter for the system report
¤ Select the events you want to log. If you
do not know precisely where the cause
of the error could be, mark all events.
¤ Click on Set to activate your settings on
the screen.
The changes take effect with the next
system event.
Try to reproduce the error that occurred.
The report will be stored on your SysLog
server. Provide this with the error ticket.