Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / AdminIVZ.fm / 11/7/18 Content Content N870 IP PRO Multicell System – Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Planning your DECT wireless network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 N870 IP PRO – overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / AdminIVZ.fm / 11/7/18 Content Online services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 System settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Web configurator access rights . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / introduction.fm / 12/4/18 N870 IP PRO Multicell System – Introduction N870 IP PRO Multicell System – Introduction N870 IP PRO is a DECT multicell system for connecting DECT base stations to a VoIP PBX. It combines the options of IP telephony with the use of DECT telephones.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / introduction.fm / 12/4/18 N870 IP PRO Multicell System – Introduction • N870 IP PRO DECT manager • • Template Module, Version 1.2, 11.09.2018 • Management unit for a group of base stations. At least one DECT manager must be used for each installation.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / introduction.fm / 12/4/18 N870 IP PRO Multicell System – Introduction • Forming clusters Template Module, Version 1.2, 11.09.2018, A cluster defines a set of base stations of a DECT manager that shall synchronise in order to perform handover, roaming and overload balancing. Handover means to switch a handsets DECT connection to a new base station during a call. Roaming means to connect a handset in idle mode via a new base.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / introduction.fm / 12/4/18 N870 IP PRO Multicell System – Introduction Deployments The N870 IP PRO Multicell System deployment can be delivered in different stages of expansions. Small Medium Large – XXL Embedded INT + DM device with activated DECT base station Embedded INT + DM device without DECT base station Virtualised integrator INT DM INT DM . . . BS 1 1 2 BS 2 .... ... BS 10 50 ..........
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / introduction.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / introduction.fm / 12/4/18 N870 IP PRO Multicell System – Introduction N870 IP PRO – overview Front Device button Set the device role; reset the device ¢ page 15 LED displays Operation status of the device ¢ page 17 Top LAN and power cable slot Connecting the device ¢ page 12 Template Module, Version 1.2, 11.09.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 First steps First steps Package content • One N870 IP PRO • It can be used as DECT management system or as base station Security leaflet The N870 IP PRO devices are powered by Power over Ethernet (PoE). If you do not use an Ethernet switch with PoE functionality and require a power adapter to connect to the mains power supply, you can order this as an accessory ( page 116).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 First steps 8 Register the base stations at the DECT manager Note: The base stations will go offline for the duration of firmware update. Further configuration of base stations (step 9) could be done via the Integrator Web-UI (and database). But the base stations cannot learn new settings, until they have finished their offline status in case of a firmware update.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 First steps Mounting the device Read the "N870 IP PRO - Site Planning and Measurement Guide" before you start installing the devices. • When installing the base stations, please take into account the technical conditions for posi• • • tioning and the installation guidelines, which are described in the "N870 IP PRO - Site Planning and Measurement Guide".
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 First steps Connecting to the LAN DECT manager and base stations must be connected to the same Ethernet or virtual LAN sharing a common broadcast domain. If you intend to use DECT-LAN synchronisation, please consider the requirements mentioned in section "LAN-based synchronisation" (¢ page 43). You can connect the devices to your local network via a router, switch, or hub.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 First steps Data protection notice Once the device is connected to the Internet, it automatically contacts the Gigaset support server to make it easier for you to configure the devices and to enable communication with Internet services.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 First steps Defining the device role On delivery all N870 IP PRO devices are configured as base station. To set up the DECT multicell system at least one device must be configured as DECT manager. Detailed information on device roles: ¢ page 4. You use the device button on the front side to change the role of the device.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 First steps Wall mounting N870 IP PRO is intended for wall mounting. After connecting the LAN cable and setting the device role you can place it to the destined location. 110 mm max. ø 8 mm max. 3 mm max. ø 4 mm Template Module, Version 1.2, 11.09.2018, Fix the device to the wall with two screws: ¤ ¤ Drill holes with the vertical spacing of 110 mm. ¤ Hang the device on the screws.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 Operation hints Operation hints Light emitting diodes (LED) Depending on the device role the LEDs on the front side show different operational states. The LEDs can have three different colours (red, blue, green) or can be off. DECT manager and base stations LED 1 (left) 0.5 s 0.5 s 0.5 s LED 2 (right) 0.5 s 0.5 s 0.5 s 0.5 s Description 0.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 Operation hints DECT manager (with DECT) LED 1 (left) 0.5 s 0.5 s 0.5 s LED 2 (right) 0.5 s 0.5 s 0.5 s 0.5 s Description 0.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / starting.fm / 12/4/18 Operation hints Emergency reset to factory settings When the device is booting ¤ Template Module, Version 1.2, 11.09.2018 ¤ ¤ Press the device button for at least 10 seconds until all LEDs switch off . . . the device is now in programming mode. release the button Press the device button until the LED lights green Press the device button for at least four seconds . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_intro.fm / 12/4/18 Configuring the system Configuring the system System settings are made via the web configurator of the N870 IP PRO (¢ page 20) and cannot be changed using the handsets. This applies in particular for: • Registering and de-registering the handset at the telephone system, handset name. • All settings for the VoIP account used by a handset for calls. • Configuration of online directories.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_intro.fm / 12/4/18 Configuring the system ¤ ¤ Launch the web browser on your PC/tablet. Enter the current IP address for the Integrator/DECT manager in the address field of the web browser (for example: http://192.168.2.10).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_intro.fm / 12/4/18 Configuring the system Showing/hiding the navigation menu On each web configurator page a side menu on the left allows you to navigate through the available functions. The menu currently used is unfolded and the currently selected menu entry is coloured orange. The navigation menu can be displayed permanently or can be hidden in the case the pointer is moved out of the menu area.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_intro.fm / 12/4/18 Configuring the system Working with lists Changing the appearance of the list Filtering the list: ¤ Enter a search item (full field content) in the text field . . . only entries containing text matching the search item in any column are shown in the table.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_intro.fm / 12/4/18 Configuring the system Web configurator menu overview Menu options that are available also in the DECT managers user interface are highlighted grey. The other options are available only on the Integrator.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_Network.fm / 12/4/18 Network administration Network administration IP and VLAN settings This page is used to integrate the DECT multicell system into your company‘s local network. ¤ Settings Network IP/LAN If you change the IP address of the device or an error occurs when you are changing the IP settings, the connection to the web User Interface may be lost.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_Network.fm / 12/4/18 Network administration Subnet mask The Subnet mask specifies how many parts of an IP address the network prefix must comprise. For example, 255.255.255.0 means that the first three parts of an IP address must be the same for all devices in the network, while the last part is specific to each device. In subnet mask 255.255.0.0, only the first two parts are reserved for the network prefix.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_Network.fm / 12/4/18 Network administration VLAN Details in this area are only required if you connect your phone system to a local network that is divided into virtual subnetworks (VLAN – Virtual Local Area Network). In a tagged VLAN, data packets are assigned to the individual subnetworks via tags (markings) that consist of a VLAN identifier and the VLAN priority, amongst others.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration DECT manager configuration DECT manager configuration is only necessary in large installations with more than one DECT manager. It is only available on the Integrator user interface.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration The actual values are shown in the Bases limit, Handsets limit and Calls limit columns. Bases limit Maximum number of base stations that are allowed to be assigned to the DECT manager. The column is hidden by default. Handsets limit Maximum number of handsets that are allowed to be registered at the DECT manager. The column is hidden by default.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration Changing the number of list entries ¤ On the right side below the list select the maximum number of entries that should be displayed on a page (10, 25, 50, 100). Browsing through the list If there are more list entries than the selected number, you can browse through the whole table page by page. The number of pages is shown below the list. The current page is highlighted.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration Password The password must be entered when registering the DECT manager at the Integrator. ¤ Enter a password for DECT manager registration. You should note this password to have it available, when you will have to enter the account data later at the DECT manager. RPN Group Part of the RFPI for a DECT manager.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration DECT Manager log System log The system report (SysLog) gathers information about selected processes performed by the DECT manager and base stations during operation and sends this to the configured SysLog server. Activate system log ¤ Mark/unmark the check box to activate/deactivate the logging function.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration DECT manager registration You can now register the DECT managers at the Integrator. ¤ ¤ ¤ Assign the device role Base station and DECT manager with dynamic IP settings to the devices that are defined to act as DECT manager ( page 15). Enter the IP address for a DECT manager device in the address field of the web browser and login ( page 21).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration DECT manager synchronisation This page allows you to configure external synchronisation references for synchronisation clusters of your DECT managers. This way you could configure inter DECT manager synchronisation rules, to get base stations of multiple DECT managers in sync. Cluster-internal synchronisation is defined via base station synchronisation ( page 42).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration Actions Adding a synchronization reference to the list ¤ Click on Add . . . the DECT manager synchronization page is opened ( page 30). Deleting a synchronization reference from the list ¤ Select the check box next to the sync reference you want to delete. Multiple choice is possible. Click on Delete Confirm with Yes . . . all selected sync references are deleted.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_DM.fm / 12/4/18 DECT manager configuration Cluster ¤ For a new entry: Select a cluster number of the selected DECT manager. Only one synchronisation reference can be set for a cluster. For an existing entry: The cluster number of the selected DECT manager is shown.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Base stations The Integrator automatically recognises the base stations within the network. Base stations need to be confirmed, activated and synchronised. The menu is only available in the Integrator user interface. Base stations administration Use the following web configurator page to assign base stations to the DECT manager.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Actions Editing base station data ¤ Click on next to the base station you want to edit . . . the data page for the base station is opened ( page 39). Deleting base station ¤ Select the check box of one or more base stations Click on Delete Confirm with Yes . . . All selected base stations are deleted. They are shown in the list of pending base stations again.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations ¤ On the right side below the list select the maximum number of entries that should be displayed on a page (10, 25, 50, 100). Browsing through the list If there are more list entries than the selected number, you can browse through the whole table page by page. The number of pages is shown below the list. The current page is highlighted.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Status Synchronization status of the base station: 0 1 2 3 4 Offline Deactivated No sync Sync Sync overload Not available Available, but not activated Activated, but not synchronised Activated and synchronised Synchronised, but DECT overload IP address Current IP address of the Base station.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations The following data can be edited Name / Location This name should make it easier to assign the base station within the logical and spatial structure of the DECT network. ¤ In the text field enter a descriptive name or description for the base station. Value: max.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Base station synchronisation Synchronisation and the logical structuring of the base stations in clusters are prerequisites for the functioning of the multicell system, intercell handover, and (over)load balancing. Overload balancing means that a handset can roam to a free base, when current base is fully loaded and cannot accept further handset connections.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations DECT-based synchronisation To relay DECT synchronisation signals from base station A to base station B, base station B must be able to receive signals from base station A with sufficient signal quality. DECT manager and base stations must be connected to the same Ethernet or virtual LAN sharing a common broadcast domain.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Requirements for LAN synchronisation Minimum packet delay jitter is crucial for successful synchronisation over LAN. As multiple LAN traffic parameters could have an impact on packet delay and its jitter, specific switches and maximum number of switch hops are required, to guarantee sufficient maximum packet delay jitter.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Scenarios for LAN/DECT synchronisation hierarchy Scenario 1: Pure LAN synchronisation Use such a configuration, if all requirements for LAN synchronisation are fulfilled and the radio coverage is not stable enough to ensure reliable synchronisation.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Scenario 2: Pure DECT synchronisation Use such a configuration if your environment ensures a stable DECT over the air synchronisation or your LAN does not fulfil the requirements for LAN synchronisation.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Scenario 3: Mixed Use such a configuration, if your environment is mainly able to synchronise via DECT but there are particular circumstances which cannot always guarantee reliable DECT synchronisation, e.g., a passage through a fire door. For all base stations on levels lower than the LAN master you can individually decide whether it should be synchronised via DECT or LAN.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations List of synchronised base stations All activated base stations contained in the Connected base stations list ( the Base station synchronisation list. ¤ Settings Base stations page 37) appear in Synchronisation For each registered base station the following information is shown: MAC address Hardware address of the base station.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_basestations.fm / 12/4/18 Base stations Actions Setting up the base station synchronisation ¤ ¤ ¤ ¤ Select the cluster to which the base should be assigned to from the Cluster option menu. Base stations only synchronise within the same cluster, meaning that a handover of a handset from one cluster to a neighbouring cluster is not possible. The DECT multicell system can manage up to nine clusters.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_provider.fm / 12/4/18 Provider and PBX profiles Provider and PBX profiles Only available in the Integrator user interface. You can use up to ten different VoIP PBX or VoIP provider profiles, e.g. • your company's VoIP PBX • and/or public providers from which you have requested VoIP services. This page allows you to create a list of systems providing VoIP connections and other services for your phones.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_provider.fm / 12/4/18 Provider and PBX profiles Proxy server address The SIP proxy is your VoIP provider's gateway server and the first SIP server, where the device should send SIP requests and expects to receive requests. ¤ Enter the IP address or the (fully qualified) DNS name of your SIP proxy server (max. 74 characters, 0 - 9, a - z, A - Z, -, ., _). Examples: 10.100.0.45 or sip.domain.net or sipproxy01.domain.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_provider.fm / 12/4/18 Provider and PBX profiles Redundancy settings Redundancy - DNS query VoIP providers provide SIP server redundancy for load balancing and service reliability. SIP servers can be identified by DNS using different queries: A Records just the specified IP addresses and the related port numbers. SRV + A Finds an available server port for the specified proxy and registration server.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_provider.fm / 12/4/18 Provider and PBX profiles If the Outbound server address field is empty, the system behaves independently of the selected mode, as with Outbound proxy mode = Never.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_provider.fm / 12/4/18 Provider and PBX profiles Settings for codecs The voice quality of VoIP calls is mainly determined by the codec used for the transmission and the available bandwidth of your network connection. A "better" codec (better voice quality) means more data needs to be transferred, i.e. it requires a network connection with a larger bandwidth.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_provider.fm / 12/4/18 Provider and PBX profiles RTP Packetisation Time (ptime) Length of time in milliseconds represented by the audio data in one packet. ¤ Select the size of RTP packets to send. Select between 10 / 20 / 30 ms. Signalling options for 'Hold' in Session Description Protocol (SDP) Call hold means that a user requests to put an active call on hold.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_provider.fm / 12/4/18 Provider and PBX profiles CSTA Computer Supported Telecommunications Applications is a standard for the interaction between a computer and a PBX, independently from the manufacturer. If your PBX provides CSTA applications to be used by the registered handsets you have to activate the standard here. Account data for handset access can be configured for each handset ( page 64).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices Mobile devices You can use the web configurator to register all handsets at the DECT network and for a VoIP connection. Use the add function of the Administration page to register single handsets or use the Registration Centre to register groups of handsets in one process. You can edit the settings for handsets, deactivate or delete them and make further settings e.g.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices Actions Adding a handset to the list ¤ Click on Add . . . the mobile devices data page is opened ( page 59). Copying handset data for another configuration ¤ Select the check box next to the handset whose settings you want to copy. Click on Copy . . . the mobile devices data page is opened ( page 59).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices Displaying/ hiding columns: ¤ Click on the View option menu on the right Select the columns you want to be displayed in the table ( / = displayed/hidden). Names of columns which cannot be hidden are greyed out. Changing the number of list entries ¤ On the right side below the list select the maximum number of entries that should be displayed on a page (10, 25, 50, 100).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices Registering handsets ¤ ¤ ¤ ¤ Enter an IPUI, if you want to restrict the registration to a specific handset. Enter an authentication code manually or generate it via the Generate random PIN button. Enter all configuration data for the handset. Click on Register now. The handset with the matching IPUI is now allowed to register.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices RegStatus DECT registration status of the handset entry. The option menu allows you to change the status. Status Meaning / possible action to change the status To register The system is ready to register a handset using these settings. Not registered ¤ Select Not registered to disable registration. No registration possible.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices VoIP provider ¤ ¤ Choose a configured VoIP PBX/provider from the option menu. The connection must be configured on the Provider or PBX profiles page ( page 50). Enter the access data for the VoIP account in the relevant fields. These fields may vary depending on the PBX/provider profile. Authentication name ¤ Specify the SIP authentication (HTTP digest) name.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices LDAP authentication Up to 10 directories in LDAP format can be provided by the phone system. The access to a corporate directory can be provided individually for specific handsets. Selected LDAP book ¤ Select the LDAP directory to be provided on the handset from the option menu. At least one LDAP directory must have been set-up ( ).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices Missed calls and alarms You can define if missed and accepted calls should be counted and if new messages of specific types should be indicated via the MWI LED on the handset’s message key. ¤ ¤ Select Yes/No next to Missed calls count/Accepted calls count, to activate/deactivate the call counter for missed and accepted calls.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_mobileDevices.fm / 12/4/18 Mobile devices Handset Registration Centre The registration centre allows you to register groups of handsets in one registration process. All handsets which are listed in the mobile devices list and have the registration status To register or Registering can be registered together.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_telephony.fm / 12/4/18 Telephony settings Telephony settings The menu is only available in the Integrator user interface. General VoIP settings ¤ Settings Telephony VoIP This page allows you to make some general settings for the VoIP connections. SIP port ¤ Enter the SIP port used for VoIP connections. Range: 1-65535; Default: 5060 Secure SIP port ¤ Enter the SIP port used for secure VoIP connections (TLS).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_telephony.fm / 12/4/18 Telephony settings Security settings The phone system supports the establishment of secure voice connections over the internet via TLS certificates. Thereby, public and private keys are used to encrypt and decrypt the messages that are exchanged between SIP entities. The public key is contained within the certificate of an IP entity and is available for everyone.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_telephony.fm / 12/4/18 Telephony settings Call settings On this page you can make advanced settings for VoIP connections. ¤ Settings Telephony Call settings Call transfer Participants can transfer a call to another participant as long as the PBX/provider supports this function. The call is transferred using the handset menu (via the display key) or using the R key.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_telephony.fm / 12/4/18 Telephony settings Area Codes If you use VoIP to make a call to the fixed line, you may also have to dial the area code for local calls (depending on the provider). You can set your telephone system so that the access code is automatically predialled when any VoIP call is made in the same local area, and also for national long-distance calls.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_telephony.fm / 12/4/18 Telephony settings XSI services BroadSoft XSI (Xtended Service Interface) allows remote applications to integrate with BroadSoft services to perform telephony-related actions and to be notified about telephony events. N870 IP PRO enables the use of XSI services to provide the user with XSI directories and call lists.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_onlineDirectories_Gigaset.fm Online directories Online directories N870 IP PRO allows you to set up up to ten corporate directories in LDAP format, a public and a corporate directory in XML format, as well as different XSI directories and make them available to the registered handsets. Use the handset settings ( page 61) to specify which keys are to call up the directory.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_onlineDirectories_Gigaset.fm Online directories User access data If you want to define access data that have to be used by all users: ¤ Enter the access data for the LDAP directory in the Username and Password fields (max. 254 characters each). If you want to use individual access data for each handset, the access data is to be set during the handset configuration ( page 63).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_onlineDirectories_Gigaset.fm Online directories Name filter The name filter decides which attribute is used for the search. Example: (displayName=%). The percent sign (%) is replaced by the name or part of the name entered by the user. If a user enters the letter "A", for example, all entries in which the attribute displayName begins with "A" are searched for in the LDAP database.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_onlineDirectories_Gigaset.fm Online directories Example: Data of an directory entry on the LDAP server: displayName Peter Black telphoneNumber givenName Peter mobile sn Black ... 0891234567890 012398765432 Attribute definition in the Web configurator: Display format %sn, %givenName; %telephoneNumber/%mobile The entry is shown on the handset as follows: Black, Peter; 0891234567890/012398765432 Max.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_onlineDirectories_Gigaset.fm Online directories Online directories in XML format A public and/or a corporate online directory in XML format can be made available to the user. Use this page to enter the provider's details and a name for the directory. ¤ ¤ Settings Online directories XML Select Public or Corporate Directory name ¤ Enter a name for the directory.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_onlineDirectories_Gigaset.fm Online directories Directory name Template Module, Version 1.2, 11.09.2018, ¤ 76 For the selected XSI directories enter a name in the Directory name field. This is the name under which the directory will be displayed on the handsets.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_onlineServices.fm / 12/4/18 Online services Online services Additional functions as Info services, PBX control, and customer specific RAP (XHTML) applications can be made available to the user via the handset menu Info Centre . For this purpose four additional menu entries can be defined that will be inserted into the handset user interface. The additional functions must be available as well formatted XHTML pages.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings System settings Web configurator access rights On this page you define the access rights for the web configurator user interface. ¤ Settings System Web configurator Changing the web configurator password For security reasons, you should frequently change the password for web configurator access. There are two user roles with different user IDs, admin and user ( bled by default.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Activated if password is longer than 7 characters The CLI access is automatically enabled if you have entered a valid password that has more than seven characters and click on the Set button. = enabled; = disabled CLI password ¤ Enter a password for the administrator access to the configuration via SSH. Value: min. 8, max.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Provisioning and configuration Only available in the Integrator user interface. Provisioning is the process for uploading the necessary configuration and account data to the VoIP phones (here the DECT bases). This is done by means of profiles. A profile is a configuration file that contains VoIP phone-specific settings, VoIP provider data as well as user-specific content.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Security Only available in the Integrator user interface. The page allows you to organise the certificates used for secure internet communication and to define the credentials for HTTP authentication.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Import local certificate You can make available further certificates to your phone system. The certificates must have been downloaded to your computer before. ¤ Click Browse... and select the local certificate file from your computer‘s file system click on Upload . . . the selected certificate file is loaded and, depending on its type, added to one of the certificate lists.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Date and time Only available in the Integrator user interface. By default, the system is configured so that the date and time are transferred from a time server on the internet. The page allows you to change the time servers, to set your time zone, and to make arrangements in case the internet time servers are not available.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Firmware Regular updates to the firmware for the Integrator/DECT manager and base stations are provided by the operator or supplier on a configuration server. You can upload these updates onto the Integrator/DECT manager as required. If a firmware update is provided in the form of an update file, you can store it on your computer and download it from there.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings The firmware update may take up a longer period. Do not disconnect the devices from the local network during this time. For test reasons (e.g. for testing a new release) it is possible to have a specific firmware version on a DECT manager subsystem which may be different from the rest of the system.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Browsing through the list If there are more list entries than the selected number, you can browse through the whole table page by page. The number of pages is shown below the list. The current page is highlighted. ¤ ¤ Click on Previous or Next to scroll through the list page by page. Click on a specific page number, to go to the desired page directly.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Save and restore Only available in the Integrator user interface. This page allows you to save and restore the system configuration.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings DECT settings Only available in the Integrator user interface. Changing one of these settings requires a restart of the system. Ongoing calls will be cancelled. ECO DECT ECO DECT is an environment-friendly technology which reduces the power consumption and enables a variable reduction of transmission power.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / settings_system.fm / 12/4/18 System settings Enhanced Security - Automatic release for non-encrypted calls ¤ Activate/deactivate the option. Activated: If encryption is activated, it will be released in the case that a call is initiated by a device that is not supporting encryption. Deactivated: Encryption is never released.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / dignostics.fm / 12/4/18 Diagnostics and troubleshooting Diagnostics and troubleshooting Status information The web configurator provides a status page with important information on the multicell system operation and the connected devices. ¤ Status Overview The following information is provided.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / dignostics.fm / 12/4/18 Diagnostics and troubleshooting Base station events Only available in the Integrator user interface. This page displays counters for diagnostic purposes relating to various events that affect the base stations, e.g. active radio connections, handovers, unexpectedly terminated connections, etc.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / dignostics.fm / 12/4/18 Diagnostics and troubleshooting Actions Downloading the information in MIB format For further processing of the statistic data using a MIB browser (Management Information Base) you can download the data in MIB format (Managed Objects). ¤ Click on Download MIB Select the location where the MIB file should be stored using the system file selection dialogue.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / dignostics.fm / 12/4/18 Diagnostics and troubleshooting Displaying/ hiding columns ¤ Click on the View option menu on the right Select the columns you want to be displayed in the table ( / = displayed/hidden). Names of columns which cannot be hidden are greyed out. Incidents Only available in the Integrator user interface.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / dignostics.fm / 12/4/18 Diagnostics and troubleshooting System log and SNMP manager Only available in the Integrator user interface. The system report (SysLog) gathers information about selected processes performed by the DECT managers and base stations during operation and sends this to the configured SysLog server.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / dignostics.fm / 12/4/18 Diagnostics and troubleshooting Storing management information in MIB format You can store management information for all base stations in MIB syntax. Template Module, Version 1.2, 11.09.2018 ¤ Click on Download MIB Select the location where the MIB file should be stored using the system file selection dialogue . . . the file with the MIB information is stored in TXT format.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / migration.fm / 12/4/18 Migration Migration In order to migrate a small or medium N870 IP PRO Multicell System multicell system with one single DECT manager into a multi DECT manager installation, please perform the following steps: 1 Export the base station and handset configuration of your current installation ¤ Settings Base stations Administration (¢ page 38) ¤ Settings Mobile devices Administration (¢ page 58).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / telephony.fm / 12/4/18 Using a handset connected to an N870 IP PRO base Using a handset connected to an N870 IP PRO base The functions of your N870 IP PRO are available on the registered handsets. The functions of the telephone system are added to the handset menu. Handset-specific functions, e.g., local directory or organiser, are not described here. Information about this will be found in the relevant handset user guide.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / telephony.fm / 12/4/18 Using a handset connected to an N870 IP PRO base Dialling from the redial list The redial list contains the numbers last dialled with the handset. ¤ Briefly press the Talk key . . . the redial list is opened . . . use to select an entry Press the Talk key If a name is displayed: ¤ View . . . the number is displayed . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / telephony.fm / 12/4/18 Using a handset connected to an N870 IP PRO base Accepting calls Incoming calls for the connection assigned to your handset are signalled. ¤ Press the Talk key Switch off ringtone: ¤ Reject a call: ¤ to accept the call. Silence . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / telephony.fm / 12/4/18 Using a handset connected to an N870 IP PRO base Call swapping Switching between two calls. The other call is placed on hold. ¤ ¤ During an external call, dial the number of a second participant (consultation call) or accept a waiting caller . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / telephony.fm / 12/4/18 Using a handset connected to an N870 IP PRO base Message indication Notifications about accepted and missed calls, missed alarms and messages on the network mailbox are saved in messages list and can be displayed on the handset display.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / telephony.fm / 12/4/18 Using a handset connected to an N870 IP PRO base Opening directories via the menu Depending on the handset used you can access all available directories also via the handset's menu: . . . use to select Directory . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example LDAP directory – configuration example To allow the entries of an LDAP directory to be displayed on the handsets, you will need to configure the phone’s LDAP client.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example LDAP Search base (BaseDN) The LDAP Search base (BaseDN) parameter specifies the starting point for the search in the LDAP directory tree. This starting point must be defined on the LDAP server and entered here for the LDAP client according to the server configuration.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example Filters With filters you define criteria by which the phone searches for certain objects in the LDAP database • The name filter determines which attributes are used in the search for directory entries. • The number filter specifies which attributes are used for the automatic search in the LDAP database when phone numbers are entered.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example Filter format A filter consists of one or more criteria. A criterion defines the LDAP attribute in which the entered string is to be searched for, e.g. sn=%. The percent sign (%) is a placeholder for the user input.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example Name filter The name filter determines which attributes are used for the search in the LDAP database. Examples: (displayName=%) The attribute displayName is used for the search. The percent sign (%) is replaced with the name or part of the name entered by the user. If you enter e.g.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example Attributes For a directory entry (an object), a series of attributes are defined in the LDAP database, e.g. surname, first name, phone number, address, company etc. The set of all attributes that can be stored for an entry is stored in the schema of the relevant LDAP server.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example Specifying attributes for display on the phone In the web configurator you specify which of the available attributes from the LDAP database are to be queried and displayed on the phone. ¤ ¤ For each attribute of a directory entry, select the appropriate attribute from the LDAP database. There are predefined settings at choice.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example Entries in the directory The following description shows an example for the display of an LDAP directory on a handset. The menu shows all directories that have been set up and activated on the Online directories page in the web configurator. Each one appears with the name entered under Directory name in the web configurator (¢ page 103).
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / LDAP_example.fm / 12/4/18 LDAP directory – configuration example Displaying a directory entry ¤ ¤ Use to select the entry you want. Press the display key View or the navigation key or ¤ Press the display key Options View The directory entry is displayed with its detailed information. Only attributes for which a value is stored are shown (¢ page 105). ¤ ¤ Use to scroll through the entry.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / appendix_legal.fm / 11/7/18 Appendix Appendix Safety precautions Read the safety precautions and the user guide before use. Comprehensive user guides for all telephones and telephone systems as well as for accessories can be found online at gigasetpro.com in the Support category. We thereby help to save paper while providing fast access to the complete up-to-date documentation at any time.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / appendix_legal.fm / 11/7/18 Appendix Authorisation Voice over IP telephony is possible via the LAN interface (IEEE 802.3). This device is intended for use worldwide. Use outside the European Economic Area (with the exception of Switzerland) is subject to national approval. Country-specific requirements have been taken into consideration.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / appendix_legal.fm / 11/7/18 Appendix Care Wipe the device with a damp cloth or an antistatic cloth. Do not use solvents or microfibre cloths. Never use a dry cloth; this can cause static. In rare cases, contact with chemical substances can cause changes to the device’s exterior. Due to the wide variety of chemical products available on the market, it was not possible to test all substances.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / appendix_technical.fm / 11/7/18 Technical data Technical data Specifications Power consumption Operation as N870 IP PRO (DECT manager) < 3.8 W Operation as N870 IP PRO (base station) < 3.8 W General specifications DECT Manager and base stations Power over Ethernet PoE IEEE 802.3af < 3.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / appendix_technical.fm / 11/7/18 Accessories Accessories Power adapter You only need a power adapter if your devices are not powered by PoE (Power over Ethernet). EU: Item number: C39280-Z4-C706 UK: Item number: C39280-Z4-C745 N720 IP PRO Site Planning Kit (Site Planning Kit) Equipment for planning and analysing your DECT multicell system.
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / AdminSIX.fm / 11/7/18 Index Index Template Module, Version 1.2, 11.09.2018 A Access code . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Access data for LDAP server . . . . . . . . . . . . . . 103 Activating base station . . . . . . . . . . . . . . . . . . . 41 Additional attributes . . . . . . . . . . . . . . . . . . . 109 Address of LDAP server . . . . . . . . . . . . . . . . . 103 AND operator . . . . . . . . . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / AdminSIX.fm / 11/7/18 Index Column displaying/hiding23, 29, 35, 38, 49, 59, 85, 93 Company directory . . . . . . . . . . . . . . . . . . . . . 71 company, attribute . . . . . . . . . . . . . . . . . 74, 108 Conference . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Conference call end . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 two external calls . . . . . . . . . . . . . . . . . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / AdminSIX.fm / 11/7/18 Index friendlyCountryName . . . . . . . . . . . . . . . . . . . 74 friendlyCountryName, attribute . . . . . . . . . . . 108 G G.711 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 G.722 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 enabling . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 G.729A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / AdminSIX.fm / 11/7/18 Index MIB (Management Information Base) . . . . . 32, 95 MIB format, statistics . . . . . . . . . . . . . . . . . . . . 92 Migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Mobile devices . . . . . . . . . . . . . . . . . . . . . . . . . 5 number . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 mobile, attribute . . . . . . . . . . . . . . . . . . . 74, 108 Multicell system . . .
Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / AdminSIX.fm / 11/7/18 Index Search base. . . . . . . . . . . . . . . . . . . . . . . . . . 104 Search mode . . . . . . . . . . . . . . . . . . . . . . . . . 110 Search start point . . . . . . . . . . . . . . . . . . . . . 104 Secure Real Time Protocol . . . . . . . . . . . . . . . . 51 Secure Shell (SSH) . . . . . . . . . . . . . . . . . . . . . . 78 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Template Module, Version 1.2, 11.09.2018 / ModuleVersion 1.0 Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XXXX / cover_back.fm / 11/7/18 Issued by Gigaset Communications GmbH Frankenstr. 2a, D-46395 Bocholt © Gigaset Communications GmbH 2018 Subject to availability. All rights reserved. Rights of modification reserved. www.gigasetpro.