User's Manual

EK-MFR/1 Arch.2573
Rev. E of 22/06/2007
Sh. 25 of 35
501-000658/MN
Eurotek s.r.l.
7.3.3 Snmpget
Allows to read the variable value of a board inserted in the EK-MFR/1. To execute this command
the following string must be inserted:
snmpget -v1 -c public 192.168.1.7 1.3.6.1.4.1.19222.1.(slot+2).(variable number.)
The syntax of the command line is reported below:
snmpget :
command name
-v1 -c public :
fixed string
192.168.1.7 :
IP address of EK-MFR/1
1.3.6.1.4.1.19222.1.:
fixed string
(slot+2) :
the number of the slot (plus 2) with the variable to read.
For example, to read a variable value of the slot number 4 the
label (slot+2) will be set to 6 value.
(variable number) :
the number of the variable to read
We suppose to read the constellation variable value of the EK-UNM/1 board, inserted in the slot
number 4 of the EK-MFR/1. The number of the constellation variable is 5 (EK-UNM/1 user’s
handbook, chapter 5, board menu), so the command to digit will be:
snmpget -v1 -c public 192.168.1.7 1.3.6.1.4.1.19222.1.6 5
When the command is launched, the screen of the terminal unit returns this message:
SNMPv2-SMI::enterprises.19222.1.1.6.3 = STRING: "16QAM"
8. WEB INTERFACE
The EK-MFR/1 system supplies a web interface software tool (All4Digit Software Tool), that allows
to obtain a complete view of the system characteristics through the use of the web pages. The web
pages allows to read and modify the variables of every slot inserted in the EK-MFR/1 unit. To do
this, it is necessary to connect the EK-MFR/1 with a terminal unit (PC), by the Ethernet 10/100
Base T interface. When the connection is executed and the general switch (front panel description)
is turned on, it is necessary to launch any internet browser (internet explore for example) and to
digit the following command line:
http://192.168.1.7
EK-MFR/1 IP address
(Network menu)
When the command is executed, the password dialog box appears on the screen: