Installation
3 Install EPROM IC (one per logic board) at position U7, orienting notch on chip with
indication mark on board as shown on Figure 27.
4 Install a jump jack on JP-11 (Figure 27) for each side of unit, as needed in order to Cold Start
the unit.
Note: Jumper on JP-11 informs the CRIND that a system Cold Start is present.
5 Restore power to the unit. Refer to MDE-2540 The Advantage, Legacy, and MPD Series
Owners Manual for details on restoring system power.
6 Observe that CRIND BIOS software installs and runs properly. Refer to MDE-2562 CRIND
Service Manual for details on CRIND BIOS installs and prompts.
7 Upon receiving a prompt from the CRIND BIOS to remove the Cold Start jumper, remove
power from the unit. Refer to MDE-2540 The Advantage, Legacy, and MPD Series Owners
Manual for details on removing system power.
8 Once power has been removed, remove the Cold Start jumper from JP-11 on the CRIND Logic
board.
9 Restore the CRIND Tray to its original position.
Completing The Advantage Series Installation
Perform the following steps to complete installation.
1 Close and secure option and main doors.
2 Restore power to unit. Refer to MDE-2540 The Advantage, Legacy, and MPD Series Owners
Manual.
3 Test the dual head card assembly by tapping the test card against the logo. The CRIND beeper
will emit an audible beep upon performing a successful read.
4 Apply appropriate graphic logos. These are order entry items. See MDE-2620 for graphic
application instructions.