User Manual
Table Of Contents
- Manual Cover.pdf
- MDE-4939 Preliminary 050511.pdf
- FlexPay™ Contactless Module Installation and Service Manual
- Introduction
- Important Safety Information
- Mounting the FlexPay Contactless Module on Encore S Enhanced Dispenser Equipped with SPOT EMV CRIND
- Mounting the FlexPay Contactless Module on The Advantage Series Dispensers
- Mounting the FlexPay Contactless Module on Encore 300 and Encore 500 Dispensers
- Mounting the Contactless OTI Module on Encore 300 (Pre-EMV) Dispensers
- Mounting the FlexPay Contactless Module on Encore 500 S Dispensers
- Mounting the FlexPay Contactless Module on Eclipse Dispensers
- Mounting the FlexPay Contactless Module on FlexPay OPT Dispensers
- Installing the Contactless Interface Board on SCR 2
- Configuring SPOT EMV CRIND for FlexPay Contactless Module
- Verifying Functionality of FlexPay Contactless Module Through CRIND Diagnostics (Generic CRIND)
- Affixing FlexPay Contactless FCC Label
- FlexPay™ Contactless Module Installation and Service Manual
Verifying Functionality of FlexPay Contactless Module Through CRIND Diagnostics (Generic CRIND)
P
re
l
im
i
na
ry
Page 24 MDE-4939 FlexPay™ Contactless Module Installation and Service Manual · May 2011
6 Press 1 > Enter. The Test RF Card screen is displayed (see Figure 33).
Figure 33: CRIND Diagnostics - Test RF Card Screen
7 Present the RF card as shown in Figure 34.
Figure 34: Presenting the RF Card
If a valid read is made, Figure 35 is displayed.
Figure 35: CRIND Diagnostics - Successful Test RF Card Screen
If a valid read is not made, verify cable connections and power connections. Check LED
indicators for power connection, proper functioning, and so on.