User Manual
Table Of Contents
- Introduction
- Parts Lists
- Important Safety Information
- Preliminary Precautions
- Safety Symbols and Warning Words
- Prevent Explosions and Fires
- Prevent Electrical Shock and Sparks
- Hydraulic Pressure Releases and Fuel Leakage
- Protect Your Eyes
- React Quickly to Fuel Spills, Fires or Vehicle Impact
- Emergency and First Aid Information
- Warning Labels
- Working Alone
- Contacting Emergency Personnel
- Informing Emergency Personnel
- Other Useful Safety Information
- Classifying Hazardous Locations
- ASC TRIND Technology Update
- Installation Instructions For The Advantage Series Units
- Important Preinstallation Instruction.
- Removing Mobil Logo Display Cabinet
- Preparing For Installation
- Modifying Right Options Door
- Reinstalling Button
- Reinstalling Door Alarm Switches
- Installing Right Options Door
- Installing Bulkhead Grommet
- Installing Card Cage Assembly
- Installing Transmitter Cables
- Routing R20773-G2 Cables
- T20662-G2 Cable Routing In Main Cabinet
- Installation Instructions For MPD-3 Units
- Preparing Antenna Cable Connections
- CRIND® BIOS TRIND™ TIRIS Upgrade
- Dispenser Set-Up
Installation Instructions For The Advantage Series Units
Page 22 MDE-4063 TRIND TIRIS Retrofit Kit C00011-010-XXXX Installation Manual
• August 2001
P
r
e
liminary
08-2
4
-01
5 Remove four 3/8-16 bolts, lock washers, flat washers and soft aluminum flat washers securing
display cabinet to top of unit. Save all hardware except bolts for reassembly. Dispose of bolts.
6 Carefully lift and remove display cabinet. Set cabinet aside for reassembly.
Note: Logo display cabinet weighs approximately seventy-five pounds. A crew of two, on
separate ‘A’ style ladders, are required to lift and remove cabinet.
Preparing For Installation
Perform these steps for all The Advantage
®
Series units
1 Remove four hoisting brackets from top of unit by removing four bolts and washers. Dispose
of hoisting brackets. Save hardware for reassembly.
Note: On units with logo display cabinet, hoisting brackets have already been removed.
2 From ‘A’ side of unit, remove inner sheathing on left column. Set sheathing and screws aside
for reassembly.
3 Open main access doors. Refer to MDE-2531, Pump and Dispenser Start-Up/Service Manual
for access instructions.
Hoisting brackets
and 3/8” bolts
Figure 2:
Removing hoisting
brackets
Inside sheathing
and screws
‘A’ side
Figure 3:
Removing inner
sheathing
Outside sheathing