User Manual
Table Of Contents
- Introduction
- Parts Lists
- Important Safety Information
- Preliminary Precautions
- Safety Symbols and Warning Words
- Prevent Explosions and Fires
- Prevent Electrical Shock and Sparks
- Hydraulic Pressure Releases and Fuel Leakage
- Protect Your Eyes
- React Quickly to Fuel Spills, Fires or Vehicle Impact
- Emergency and First Aid Information
- Warning Labels
- Working Alone
- Contacting Emergency Personnel
- Informing Emergency Personnel
- Other Useful Safety Information
- Classifying Hazardous Locations
- ASC TRIND Technology Update
- Installation Instructions For The Advantage Series Units
- Important Preinstallation Instruction.
- Removing Mobil Logo Display Cabinet
- Preparing For Installation
- Modifying Right Options Door
- Reinstalling Button
- Reinstalling Door Alarm Switches
- Installing Right Options Door
- Installing Bulkhead Grommet
- Installing Card Cage Assembly
- Installing Transmitter Cables
- Routing R20773-G2 Cables
- T20662-G2 Cable Routing In Main Cabinet
- Installation Instructions For MPD-3 Units
- Preparing Antenna Cable Connections
- CRIND® BIOS TRIND™ TIRIS Upgrade
- Dispenser Set-Up
MDE-4063 TRIND TIRIS Retrofit Kit C00011-010-XXXX Installation Manual• August 2001 Page 65
Dispenser Set-Up
Preliminary
0
8-2
4-01
Dispenser Set-Up
Addressing Dispenser
Each dispenser on the G-SITE controller must be addressed differently; no two dispensers may
have the same address. Address is at discretion of the installer. Follow these steps:
1 From A side of unit, locate dip switches on power supply board (PCB) T20314-G1 in card
cage.
2 Using switches 2, 3, 4 and 5 address each dispenser according to the following table:
Note: Switch one in down position is stand-alone mode selected, used for service only.
Setting Baud Rate
For major oil company (MOC) TRIND installations there is no requirement to set or change
baud rate.
Switch Numbers = Value
1 = Stand-alone Mode
2 = 1
3 = 2
4 = 4
5 = 8
1
2
3
4
5
Dip switch down
Dip switch up