MDE-4063 TRIND TIRIS Retrofit Kit C00011-010-XXXX Installation Manual August 2001 Page 65
Dispenser Set-Up
Preliminary
0
8-2
4-01
Dispenser Set-Up
Addressing Dispenser
Each dispenser on the G-SITE controller must be addressed differently; no two dispensers may
have the same address. Address is at discretion of the installer. Follow these steps:
1 From A side of unit, locate dip switches on power supply board (PCB) T20314-G1 in card
cage.
2 Using switches 2, 3, 4 and 5 address each dispenser according to the following table:
Note: Switch one in down position is stand-alone mode selected, used for service only.
Setting Baud Rate
For major oil company (MOC) TRIND installations there is no requirement to set or change
baud rate.
Switch Numbers = Value
1 = Stand-alone Mode
2 = 1
3 = 2
4 = 4
5 = 8
1
2
3
4
5
Dip switch down
Dip switch up