User Manual

Table Of Contents
MDE-4063 TRIND TIRIS Retrofit Kit C00011-010-XXXX Installation Manual August 2001 Page 67
Dispenser Set-Up
Preliminary
0
8-2
4-01
Installing Cladding Cap
Cladding caps R20554-01 (quantity of 2) are used to fill the gap between the side cladding and
logo display cabinet resulting from raising cabinet during the TRIND retrofit.
Perform the following steps to install each cladding cap.
1 Replace outside sheathing with side cladding still attached, using only as many screws as
necessary to hold in place temporarily.
2 Fit cladding cap R20554-01 over top of side cladding with flat piece extended on to top of logo
display cabinet. Cladding cap will extend below top edge of side cladding.
3 Using center punch and hammer, mark two mounting holes (per unit side) on side cladding
through two existing holes in cladding cap.
4 Remove outside sheathing and attached side cladding from unit, and take to a non-hazardous
location away from the fuel island.
5 Drill holes at the points marked by the center punch for self-threading screws K85736-45.
6 Re-install the outside sheathing with side cladding attached using all screws removed during
disassembly.
7 Attach cladding cap to side cladding using K85736-45 self threading black screws.
8 Proceed to CRIND® BIOS TRIND TIRIS Upgrade on page 63.
CAUTION
If power tools are used for
assembly work must be
done at least 20" from fuel
island
Figure 20: Installing cladding cap
Pre-drilled holes for mounting
cladding cap to top of outside
sheathing with K85736-45
screws
Flat extension sits on
top of logo display
cabinet