User Manual

Page 13 MDE-4017A Mat Reader Assembly Kit C00016-XXX Installation September 2001
Installation
Pre
l
iminar
y
09/13/0
1
3 Set the jump jacks as follows (see the appropriate figure: Figure: Jump Jacks for Baud Rate
Setting - M01803A001 on page 12 or Figure: Jump Jacks for Baud Rate Setting -
M01803A002 on page 12).
4 If not daisychaining Mat Reader Interface Boxes, reinstall cover.
Note: Daisychaining is connecting the output from one Interface Box to the input of another.
Mat Reader Baud Rates
Baud Rate (Note) BAUD 1 BAUD 2 BAUD 4
4800 OUT OUT OUT
2400 IN OUT OUT
1200 OUT IN OUT
300 IN IN OUT
38400 OUT OUT IN
19200 IN OUT IN
9600 OUT IN IN
4800 IN IN IN
Note: 4800 is the default value and the Mat Reader value.
Electrostatic Discharge Damage
Working on electronics without connecting to a ground or discharging
static can damage electronic parts. Use a wrist strap.
CAUTION