Installation Instructions for The Advantage® Series Units
PRELIMINARY
FCC 11/30
Modifying Right Options Door
For 48" units without stop or call button on right options door, and all 36"
units, go to Re-installing Door Alarm Switches on page 25, if unit has door
alarm. If unit does not have door alarm, go to Installing Right Options Door
on page 25.
For 48" units with stop or call buttons previously installed, perform the
following steps.
1 Remove all hardware from new right options door according to the following
steps and save all parts for reassembly.
Remove two screws mounting door shield on rear of door.
Disconnect cable R20522-G2 from light/microreader printed circuit board
(PCB) by disconnecting J181 on cable from P181 on board.
Remove Indicator Light PCB.
Remove standoff-screws holding light/microreader board, and remove
board.
Door
shield
Light/microreader
PCB
Indicator light
PCB T20601
Strip grommet
Clear door assembly