User's Manual

Table Of Contents
The Advantage Series Installation
Page 16 MDE-3883 TRIND Retrofit Kits C00011-005
10/00
PRELIMINARY
FCC 11/30
Modifying Right Options Door On Wide Frame Units
Note: T20613-G2 door assemblies are call/stop button ready, and do not need to be
modified. Instructions are provided for modifying T20613-G1 doors for call/
stop button.
For all narrow frame units, or wide frame units without stop or call buttons or
door alarm switches, proceed to Installing Cables on page 20. For wide or
narrow frame units without stop or call units but with door alarm, proceed to Re-
installing Door Alarm Switches on page 19. For wide frame units with stop or
call button previously installed on right options door, do the following to relocate
hardware to new T20613-G1 options door.
1 Remove all hardware from new right options door according to the following steps
and save all parts for reassembly.
Remove two screws (1) mounting sheet metal antenna shield (2) on rear of
door. Save shield and screws for reassembly.
Disconnect cable R20522-G1 (not shown) from light/multi-protocol reader
printed circuit board T20601-G1 (3) by disconnecting J181 on cable from P181
on board.
Remove two standoff-screws (4) holding light/multi-protocol reader board (3),
and remove board. Save for reassembly.
Remove four screws (5) and antenna board T20524-G1(6). Save for
reassembly.
1
2
3
4
5
6
Wide Frame Right Options Door
T20613-G1