Re-installing Door Alarm Switches
For units with cash acceptors, follow these steps to re-install door alarm
assemblies on TRIND right option doors. Refer to diagram on this page for more
information. Perform each step for both A and B side right option doors.
1 Remove lock hardware from new right options door.
2 Re-install C-clips removed from old right side option doors on new door.
3 Install door alarm assembly to door alarm assembly bracket with screw
previously removed.
4 Attach door alarm assembly bracket to display board with screw previously
removed.
Note: Replace the piece of fiberboard between door alarm bracket assembly and
display board.
5 Be sure magnet does not touch door alarm door bracket. Slightly move door alarm
door bracket away, if necessary.
6 Reinstall all new right options door TRIND hardware except sheet metal cover by
reversing procedures in Step 1 of Modifying Right Options Door On Wide Frame
Units on page 16.