Dispenser Set-Up
Page 36 MDE-3883 TRIND Retrofit Kits C00011-005
10/00
PRELIMINARY
FCC 11/30
Testing TRIND
1 For The Advantage series units, if printer was removed, replace printer and reconnect two
cables and ground.
2 Restore power to unit. Refer to Pump and Dispenser Service Manual MDE-2531.
3 Restoring power with new BIOS will Cold Start the CRIND. Refer to CRIND
Service Manual MDE-2562.
Note: Cold Start is required if TRIND equipment is installed or changed.
4 Present test tag at option door from a distance of 6’’ or less. Light board should
light and flash sequentially and emit one beep. A screen prompt should appear.
Note: If light does not function properly, check to see if opposite side of unit was
activated, indicating a crossed cable.
5 When using test tag, screen will show Test Confirmed. In regular operation,
screen will display instructions to begin fueling.
Completing Installation
1 Close and secure option and maindoor.
2 Install graphics. Refer to MDE-2620 Graphics Installation for The Advantage
Series.
3 Peel backing paper off FCC label pate provided in kit.
4 Affix FCC label plate to inside frame sheathing on column under existing FCC
label.
5 Restore power to unit. Refer to Pump and Dispenser Service Manual MDE-2531.