User Manual

E) Full Scale Adjust
(Ten Turn Trimpot)
The ten turn pot R1 is the one adjustment on the Br-ANA. It sets the gain
for the Digital to Analog (D/A) converters on the board. It is set at the factory,
and should never need any adjustment after that. To set it, pick any output
and set the minimum and maximum scaling to their minimums and maxi-
mums through the configuration screen. When you send a full scale output
command to this output, you should then be able to adjust it for 10.00 volts
using The 10 turn pot R1. The adjustments for the endpoints on each of the
sixteen outputs are individually set through the setup screen.
Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485
Br-ANA Manual / December 18, 2012 10:21 AM / page 29 of 60